Aims: In patients with asymptomatic ventricular pre-excitation (VPE) persistent at exercise stress test, this study evaluates the proportion of cases with adverse conduction properties of the atrioventricular accessory pathway (AP) at invasive electrophysiological study and the long-term follow-up after they received treatment according to pre-determined criteria.
Methods And Results: Over 10 years, asymptomatic patients with VPE persistent at exercise stress test referred for invasive electrophysiological evaluation including isoproterenol (IPN) infusion were included. Ablation was planned if they had at least one of the following criteria: (i) shortest pre-excited R-R interval (SPERRI) ≤250 ms and/or (ii) inducible atrioventricular re-entrant tachycardia (AVRT). Cryoablation was electively used in para-hisian and mid-septal APs. Patients non-eligible for ablation received no therapy. Sixty-three patients (45 males; mean age 26 ± 14 years) underwent electrophysiological evaluation: 7 had fasciculo-ventricular fibres and were excluded, whereas 56 had 58 APs. Thirty-one patients (55%) were eligible and underwent successful ablation: 87% had at least the SPERRI ≤ 250 ms and 61% had at least inducible AVRT. In 15 cases (48%) the ablation criteria were met only during IPN infusion. During follow-up (73 ± 33 months), one patient was successfully retreated for resumption of VPE in the ablation group, whereas no event was observed in the group of patients who received no treatment.
Conclusion: In this subset of patients with asymptomatic VPE, invasive electrophysiological evaluation shows fast antegrade conduction over the AP and/or inducible AVRT in about half of the cases. Patients who received no therapy because of a benign electrophysiological profile had an event-free follow-up.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euu324 | DOI Listing |
Bioact Mater
May 2025
Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), Calle Sor Juana Inés de la Cruz 3, 28049, Madrid, Spain.
Millions of patients and their caretakers live and deal with the devastating consequences of spinal cord injury (SCI) worldwide. Despite outstanding advances in the field to both understand and tackle these pathologies, a cure for SCI patients, with their peculiar characteristics, is still a mirage. One of the most promising therapeutic strategies to date for these patients involves the use of epidural electrical stimulation.
View Article and Find Full Text PDFACS Sens
January 2025
Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384, PR China.
The simultaneous detection of electroencephalography (EEG) signals and neurotransmitter levels plays an important role as biomarkers for the assessment and monitoring of emotions and cognition. This paper describes the development of boron and nitrogen codoped graphene-diamond (BNGrD) microelectrodes with a diameter of only 200 μm for sensing EEG signals and dopamine (DA) levels, which have been developed for the first time. The optimized BNGrD microelectrode responded sensitively to both EEG and DA signals, with a signal-to-noise ratio of 9 dB for spontaneous EEG signals and a limit of detection as low as 124 nM for DA.
View Article and Find Full Text PDFbioRxiv
January 2025
Centre for Vision Research, Centre for Integrative & Applied Neuroscience, Vision: Science to Applications Program, Connected Minds, Department of Biology, York University, Toronto, ON M3J 1P3, Canada.
Response preparation is accomplished by gradual accumulation in neural activity until a threshold is reached. In humans, such a preparatory signal, referred to as the lateralized readiness potential, can be observed in the EEG over sensorimotor cortical areas before execution of a voluntary movement. Although well-described for manual movements, less is known about preparatory EEG potentials for saccadic eye movements in humans and nonhuman primates.
View Article and Find Full Text PDFACS Sens
January 2025
Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, Missouri 65409, United States.
Wearable sensors are increasingly being used as biosensors for health monitoring. Current wearable devices are large, heavy, invasive, skin irritants, or not continuous. Miniaturization was chosen to address these issues, using a femtosecond laser-conversion technique to fabricate miniaturized laser-induced graphene (LIG) sensor arrays on and encapsulated within a polyimide substrate.
View Article and Find Full Text PDFEnferm Intensiva (Engl Ed)
January 2025
Grupo de Trabajo de Analgesia, Sedación, Contenciones y Delirio de la Sociedad Española de Enfermería Intensiva y Unidades Coronarias (GT-ASCyD-SEEIUC), Spain; Área del paciente crítico, Reanimación y Anestesia, Hospital Universitario de Girona Dr. Josep Trueta, Girona, Spain; Departamento de Enfermería, Universitat de Girona (UdG), Girona, Spain.
Electrophysiological monitoring of pain provides objective measures that allow for pain control and adjustment of analgesia in non-communicative patients. Among the available electrophysiological devices, automated infrared pupillometry, Analgesia Nociception Index (ANI), and Nociception Level Index (NOL®) stand out. These non-invasive measurement systems analyze the sympathetic or parasympathetic nervous system response to painful stimuli by observing pupillary dilatation and reactivity (pupillometry), heart rate during respiration (ANI), or a combination of multiple parameters from the nociceptive-autonomic medullary circuit (NOL®).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!