As radiation therapy transitions from intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) it is important to consider the quality assurance (QA) of VMAT plans in light of what has previously been learned and developed in IMRT QA. This technical note assesses if IMRT based plan QA software, which has reduced the need in IMRT for phantom dose measurements on the linear accelerator, can be incorporated into VMAT QA processes. Twenty prostate cases were retrospectively planned using VMAT with one arc to deliver a prescription of 74 Gy in 37 fractions. A plan QA was performed using both (version 3.3), a software-based IMRT QA program, and (version 6.2.3.5713), a phantom-based VMAT QA tool. Outcomes assessed included the time needed to perform the QA of both the and QA methods, and agreement between planned dose and QA measured dose. On average per case, the technique needed 31.5 min to perform the VMAT plan QA, while required 3.5 min to perform the same QA. All 20 cases passed dosimetric QA using . However, using , three cases failed dosimetric QA using the departments existing IMRT QA criteria. This research has demonstrated that the IMRT QA software may be incorporated into the QA of VMAT plans, however the criteria to assess the dosimetry of the VMAT plans may need to be different to that for IMRT cases. The implication of this research for radiation therapists is to be critically aware of the differences between the plan QA requirements and methods for IMRT and those required for VMAT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4282033 | PMC |
http://dx.doi.org/10.1002/jmrs.78 | DOI Listing |
In Vivo
December 2024
Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Background/aim: HyperArc (HA) is an automated planning technique enabling single-isocenter brain stereotactic radiotherapy (SRT); however, dosimetric outcomes may be influenced by the planner's expertise. This study aimed to assess the impact of institutional experience on the plan quality of HA-SRT for both single and multiple brain metastases.
Materials And Methods: Twenty patients who underwent HA-SRT for single metastasis between 2020 and 2021 comprised the earlier group, while those treated between 2022 and 2024 constituted the later group.
Asian Pac J Cancer Prev
December 2024
Department of Physics, Lovely Professional University, Phagwara, India.
Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.
Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.
Sci Rep
December 2024
Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310000, China.
Recently, neoadjuvant short-course radiation therapy (SCRT) has emerged as a valid treatment option for patients with locally advanced rectal cancer (LARC). We assessed SCRT plans using volumetric-modulated arc therapy (VMAT) with Halcyon and Infinity medical linear accelerators (Linacs) and compared the plan quality and delivery efficiency across all cases. Thirty patients who underwent preoperative SCRT for LARC at the hospital were randomly selected.
View Article and Find Full Text PDFPeerJ
December 2024
Department of Radiation Oncology, The First Affiliated Hospital of Guangzhou Medical University, GuangZhou, GuangDong, China.
Background: This study investigates the impact of convergence mode (CM) in Eclipse (Varian Medical Systems) on the quality and complexity of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC) patients.
Methods: We retrospectively analyzed data from 21 NPC patients. For each patient, three VMAT plans with different CM settings (Off, On, and Extended) were created using identical optimization objectives.
Pract Radiat Oncol
December 2024
Mayo Clinic, Department of Radiation Oncology, Rochester, MN 55905.
Objectives: Spatially fractionated radiation therapy (SFRT) intentionally delivers a heterogeneous dose distribution characterized by alternating regions of high and low doses throughout a tumor. This modality may enhance response to subsequent whole tumor radiation in bulky and radioresistant lesions that are historically less responsive to conventional radiation doses alone. The current study presents a single institution experience with modern era SFRT using predominantly a volumetric modulated arc therapy (VMAT) lattice technique.