AI Article Synopsis

  • HVOO is a significant complication in pediatric liver transplants, and current techniques are still prone to issues despite advancements.
  • A new technique for hepatic venous reconstruction involves creating a wide longitudinal orifice in the recipient's inferior vena cava instead of using the original hepatic vein openings.
  • In a study of 210 transplants, the new method led to significantly lower rates of HVOO compared to traditional methods, highlighting its effectiveness in enhancing surgical outcomes.

Article Abstract

HVOO represents a serious critical complication of pediatric living-donor liver transplantation because open surgical repair is virtually impossible. Currently, despite several technical innovations and the introduction of triangulated anastomosis for hepatic vein reconstruction, the reported incidence of HVOO is still considerable. The aim of this study was to propose a new technique for hepatic venous reconstruction that avoids the original orifice of the recipient hepatic veins. Instead, anastomosis is performed in a newly created wide longitudinal orifice in the anterior wall of the recipient inferior vena cava. A total of 210 living related-donor liver transplantations were performed using two methods for reconstruction of the hepatic vein. Group 1 included 69 patients subjected to direct anastomosis of the orifice of the graft hepatic vein and a wide orifice created in the recipient inferior vena cava by the confluence of the orifices of the right, left, and middle hepatic veins. Group 2 included 141 patients in whom the original orifices of the recipient hepatic veins were closed, the inferior vena cava was widely opened, and a long longitudinal anastomosis was performed using two lines of continuous sutures. Diagnosis of HVOO was suspected based on clinical findings and ultrasound studies and then confirmed by liver biopsy and interventional radiology examinations. Among the 69 recipients in group 1, 16 patients died due to graft problems during the postoperative period and eight of the survivors (15.1%) presented with HVOO. In group 2 (141 patients), 21 patients died, and there were no cases of HVOO. A comparison of the incidence of HVOO between groups revealed a significant difference (p = 0.01). Hepatic venous reconstruction during pediatric living-donor liver transplantation should be performed using a wide longitudinal incision in the anterior wall of the recipient inferior vena cava because this technique eliminated anastomosis complications.

Download full-text PDF

Source
http://dx.doi.org/10.1111/petr.12429DOI Listing

Publication Analysis

Top Keywords

inferior vena
16
vena cava
16
hepatic venous
12
pediatric living-donor
12
living-donor liver
12
liver transplantation
12
hepatic vein
12
hepatic veins
12
recipient inferior
12
hepatic
9

Similar Publications

Budd-Chiari syndrome with obstruction in the inferior vena cava causes increased venous pressure in the azygous-hemiazygous system and paravertebral venous plexus, which is transmitted to the epidural venous plexus, devoid of the valves. It causes epidural venous plexus engorgement and venous congestion and may present rarely with low back pain or radiating pain. However, patients developing lower limb weakness as a complication of Budd-Chiari syndrome is an infrequent and severe presentation.

View Article and Find Full Text PDF

Engineered hiPSC-derived vascular graft brings hope for thrombosis-free vascular therapy.

Cell Stem Cell

January 2025

Department of Chemical and Biological Engineering, University of Wisconsin-Madison, Madison, WI, USA. Electronic address:

Tissue-engineered vascular conduits (TEVCs) are a promising blood vessel replacement. In a recent publication in Cell Stem Cell, Park et al. developed TEVCs comprised of decellularized human umbilical arteries lined with shear-trained, human induced pluripotent stem cell (hiPSC)-derived endothelial cells (ECs) that resisted thrombosis and exhibited patency upon grafting into the rat inferior vena cava (IVC).

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Patients at high risk of deep vein thrombosis are recommended to undergo lower-extremity ultrasonography to screen for pulmonary embolism (PE); however, there are few reports on whether this can effectively reduce the occurrence of fatal pulmonary embolism (FPE). This study aimed to assess the risk factors associated with PE and to investigate whether perioperative ultrasound screening of lower extremity veins in orthopedic patients can effectively reduce the incidence of FPE. We enrolled 137 patients with PE who underwent orthopedic surgery between 2013 and 2020.

View Article and Find Full Text PDF

Two unique presentations of renal anatomy were observed during routine cadaveric dissection. The first case presented with an ectopic malrotated left kidney supplied by supernumerary renal arteries. This kidney was drained by a circumaortic renal vein and an inferior polar vein.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!