A prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients.

Int J Emerg Med

Department of Emergency Medicine, State University of New York Upstate Medical University, Syracuse, NY 13210 USA ; EMSTAT Center, 550 East Genesee St., Syracuse, NY 13202 USA.

Published: January 2015

Background: During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital providers in these cold weather environments are likely using fluids that are well below room temperature when prehospital intravenous fluid (IVF) warming techniques are not being employed. It was hypothesized that cold ambient temperatures during winter months in the study location would lead to the inadvertent infusion of cold intravenous fluids during prehospital patient care.

Methods: Trained student research assistants obtained three sequential temperature measurements using an infrared thermometer in a convenience sample of intravenous fluid bags connected to patients arriving via EMS during two consecutive winter seasons (2011 to 2013) at our receiving hospital in Syracuse, New York. Intravenous fluids contained in anything other than a standard polyvinyl chloride bag were not measured and were not included in the study. Outdoor temperature was collected by referencing National Weather Service online data at the time of arrival. Official transport times from the scene to the emergency department (ED) and other demographic data was collected from the EMS provider or their patient care record at the time of EMS interaction.

Results: Twenty-three intravenous fluid bag temperatures were collected and analyzed. Outdoor temperature was significantly related to the temperature of the intravenous fluid being administered, b = 0.69, t(21) = 4.3, p < 0.001. Transport time did not predict the measured intravenous fluid temperatures, b = 0.12, t(20) = 0.55, p < 0.6.

Conclusions: Use of unwarmed intravenous fluid in the prehospital environment during times of cold ambient temperatures can lead to the infusion of cool intravenous fluid and may result in harm to patients. Short transport times do not limit this risk. Emergency departments should not rely on EMS agencies' use of intravenous fluid warming techniques and should consider replacing EMS intravenous fluids upon ED arrival to ensure patient safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272522PMC
http://dx.doi.org/10.1186/s12245-014-0047-yDOI Listing

Publication Analysis

Top Keywords

intravenous fluids
20
intravenous fluid
16
intravenous
9
ambient temperatures
8
transport times
8
cold weather
8
cool intravenous
8
fluids prehospital
8
outdoor temperature
8
fluids
6

Similar Publications

Background: Short peripheral catheter (SPC) placement is a routine invasive procedure in clinical settings that is crucial for administering fluids, medications, or blood components. Approximately 11% of adult patients arriving at the Emergency Department (ED) experience difficulties with intravenous access (DIVA), necessitating advanced techniques for successful placement. The Enhanced Adult DIVA (EA-DIVA) score serves as a validated tool to promptly identify patients with DIVA.

View Article and Find Full Text PDF

Acute esophageal necrosis (AEN) is an uncommon endoscopic finding characterized by a patchy or diffuse circumferential black pigmentation of the esophageal mucosa, corresponding to ischemic necrosis. It usually presents with upper gastrointestinal bleeding and is thought to be caused by a systemic low blood flow in patients with predisposing risk factors, like advanced age and cardiovascular comorbidities. After initial hemodynamic stabilization, diagnosis is established by esophagogastroduodenoscopy (EGD) with careful biopsies and histological evaluation.

View Article and Find Full Text PDF

Background: In the 21st century, disasters (particularly earthquakes, which remain the leading cause of death) continue to be among the foremost issues requiring global emergency response. While the impact of advancing technologies on the environmental and human damage caused by earthquakes is still a subject of debate, search and rescue (SAR) teams and emergency departments (ED), specifically emergency physicians (EPs), play a crucial role in the most acute management of the effects of these earthquakes on human life. This study aims to examine the injury dynamics of two catastrophic earthquakes that occurred in Turkey 24 years apart from the perspective of EPs, utilizing archival records from the SAR teams in which EPs served.

View Article and Find Full Text PDF

Introduction: Angiotensin II may reduce muscle ischemia during intermittent hemodialysis and thereby decrease the incidence and/or intensity of intradialytic muscle cramps. We aimed to test whether angiotensin II infusion during intermittent hemodialysis is safe, feasible, and effective in the attenuation of muscle cramps.

Methods: We performed a pilot, single-blinded, randomized crossover trial of patients receiving intermittent hemodialysis who frequently experience intradialytic muscle cramps.

View Article and Find Full Text PDF

Rationale: It is imperative to be cautious about the potential systemic allergic reaction caused by the combined use of Qing Kailing Injection (QKI) and clindamycin as it may be life-threatening.

Patient Concerns: A 48-year-old female with a history of hypertension was admitted to a private hospital with a fever and cough. She was diagnosed with lung infection and received QKI infusion, followed by clindamycin infusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!