Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source activity using a radionuclide activity meter are potential sources of variability, this work investigated instrumentation and acquisition factors affecting repeatability using planar acquisition of sealed sources. The calibration factor was calculated for different acquisition and geometry conditions to evaluate the effect of the source size, lateral position of the source in the camera field-of-view (FOV), source-to-camera distance (SCD), and variability over time using sealed Ba-133 sources. A small region of interest (ROI) based on the source dimensions and collimator resolution was investigated to decrease the background effect. A statistical analysis with a mixed-effects model was used to evaluate quantitatively the effect of each variable on the global calibration factor variability. A variation of 1 cm in the measurement of the SCD from the assumed distance of 17 cm led to a variation of 1-2% in the calibration factor measurement using a small disc source (0.4 cm diameter) and less than 1% with a larger rod source (2.9 cm diameter). The lateral position of the source in the FOV and the variability over time had small impacts on calibration factor variability. The residual error component was well estimated by Poisson noise. Repeatability of better than 1% in a calibration factor measurement using a planar acquisition of a sealed source can be reasonably achieved. The best reproducibility was obtained with the largest source with a count rate much higher than the average background in the ROI, and when the SCD was positioned within 5 mm of the desired position. In this case, calibration source variability was limited by the quantum noise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4437762PMC
http://dx.doi.org/10.1088/0031-9155/60/3/1325DOI Listing

Publication Analysis

Top Keywords

calibration factor
24
source
12
factors repeatability
8
calibration
8
sealed source
8
planar acquisition
8
acquisition sealed
8
lateral position
8
position source
8
variability time
8

Similar Publications

Aim: To construct a predictive model based on the LODDS stage established for patients with late-onset colon adenocarcinoma to enhance survival stratification.

Methods: Late-onset colon adenocarcinoma data were obtained from the public database. After determining the optimal LODDS truncation value for the training set via X-tile software, we created a new staging system by integrating the T stage and M stage.

View Article and Find Full Text PDF

Introduction: Functional dependence on the performance of basic activities of daily living (ADLs) is associated with increased mortality. In this study, the Barthel index and its activities discriminate long-term mortality risk, and whether changes in this index are necessary to adapt it to detect mortality risk is examined.

Methods: Longitudinal study, carried out at the Orcasitas Health Center, Madrid (Spain), on the functional dependent population (Barthel ≤ 60).

View Article and Find Full Text PDF

Background: The relationship between patient nutritional, immune, and inflammatory status is linked to tumor progression and prognosis. However, there are limited studies on the prognosis of esophageal squamous cell carcinoma (ESCC) after surgery based on the comprehensive indicators of these factors.

Aim: To develop and validate a novel nomogram based on a nutritional immune-inflammatory status (NIIS) score for predicting postoperative outcomes in ESCC.

View Article and Find Full Text PDF

Background: Inflammation is a driver of thrombosis, but the phenomenon of thromboinflammation has been defined only recently, bringing together the multiple pathways involved. models can support the development of new therapeutics targeting the endothelium and also assess the existing immunomodulatory drugs, such as hydroxychloroquine, in modulating the inflammation-driven endothelial prothrombotic phenotype.

Objectives: To develop a model for thrombin generation (TG) on the surface of human endothelial cells (ECs) to assess pro/antithrombotic properties in response to inflammation.

View Article and Find Full Text PDF

Aim: This study aims to create and validate a novel systematic immune-inflammation-nutrition (SIIN) score to provide a non-invasive and accurate prognostic tool for head and neck squamous cell carcinoma (HNSCC) patients.

Methods: 259 participants diagnosed with HNSCC from the First Affiliated Hospital of Xi'an Jiaotong University between 2008 and 2017 was included in this retrospective study. Patients were assigned to training (n=181) and validation (n=78) sets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!