Introduction: Historically, split-thickness skin grafts have been fixed onto the recipient site by suture and/or staples. Fibrin sealants have become available for the fixation in the past 10 years. Fibrin sealants have been shown to be at least as effective as staples, and recent reports show them to cause less pain. However, the product is much more expensive than traditional suture and/or staple fixation. The cost-benefit ratio of sealant has not yet been proven.

Methods: A review of charts for 202 consecutive patients was undertaken for patients with burns that were less than 10% total body surface area (TBSA) that underwent excision and grafting using fibrin sealant at the regional burn center. A historical control comprising 48 consecutive patients with burns that were less than 10% TBSA that underwent excision and grafting using staples as the only means of fixation was used for comparison. Demographics (such as age, weight, and sex), personal history of tobacco use, previous diagnosis of diabetes, type and depth of burn, TBSA, area of grafting, graft and donor locations, mesh type, rate of hematomas, rate of graft loss, rate of complete closure at 1 month, and time to discharge after surgery were recorded for each patient in both cohorts. The data were compared and statistical analysis performed for graft loss complications and number of days until the patient could be discharged home with outpatient wound care.

Results: Use of fibrin sealants has resulted in statistically significant lower rates of loss of graft at our institution. Additionally, a decrease in the number of days until discharge to outpatient wound care of nearly 2 days produced a lower cost of care in patients with less than 10% TBSA undergoing excision and grafting.

Conclusions: The use of fibrin sealants allows for fewer graft loss complications and earlier discharge in patients who have burns that are less than 10% TBSA. This decrease in hospital days results in savings, although this difference is not statistically significant.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0000000000000397DOI Listing

Publication Analysis

Top Keywords

fibrin sealants
16
patients burns
12
burns 10%
12
10% tbsa
12
graft loss
12
fibrin sealant
8
skin grafts
8
suture and/or
8
consecutive patients
8
tbsa underwent
8

Similar Publications

Burn injuries remain a major clinical problem worldwide, which require special management by experienced plastic surgeons. However, they cannot be available in every healthcare unit; consequently, there is a need for effective treatment options that could be utilized by a wide range of non-expert healthcare professionals. The aim of the present experimental study was to investigate the safety and efficacy of using a fibrin sealant (TISSEEL) compared to the conventional treatment with sulfadiazine on partial-thickness burn in a rat animal model.

View Article and Find Full Text PDF

Background: Cerebrospinal fluid (CSF) leakage frequently complicates endoscopic endonasal transsphenoidal pituitary resections, despite the use of lumbar drains, nasoseptal flaps, or commercial dura sealants. Managing this complication often requires revision surgery and increases the risk of infection. Platelet-rich fibrin (PRF), an affordable autologous biomaterial derived from the patient's blood through short, angulated centrifugation, contains growth factors and leukocytes embedded in a fibrin matrix.

View Article and Find Full Text PDF

Efficacy of Fibrin Sealant in Submental Liposuction: A Prospective Randomized Study.

Aesthetic Plast Surg

December 2024

Tokyo Chuo Beauty Clinic, K's Square Building 3F, 2-8-15 Sonezaki, Kita-ku, Osaka-shi, Osaka-fu, UmedaOsaka, Japan.

Background: The incidence rate of submental liposuction has been increasing in recent years. Although this procedure is relatively simple, serious complications, including fatalities, have been reported, primarily owing to intraoperative and postoperative bleeding.

Methods: To enhance the safety of liposuction, we examined the efficacy of Beriplast® P (CSL Behring, Melbourne, Australia), a physiological tissue adhesive fibrin sealant, in reducing postoperative swelling.

View Article and Find Full Text PDF

Background And Aims: An effective surgical adhesive must possess strength, biodegradability, flexibility, non-toxicity, and the ability to accommodate to tissue movement. However, existing adhesives in the market lack some of these crucial properties. Both synthetic cyanoacrylate and natural fibrin glue have been explored for sutureless oral surgery, but they come with specific limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!