A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spontaneous fractures in custom-made porous hydroxyapatite cranioplasty implants: is fragility the only culprit? | LitMetric

AI Article Synopsis

  • The study investigates the fragility of custom-made hydroxyapatite cranioplasty implants and how a surgeon's techniques can impact their performance.
  • The researchers created a virtual model and tested different surgical scenarios to see how discrepancies and gaps could affect the implant's load-bearing capacity.
  • Findings indicate that imprecise surgical methods can significantly increase the implant's fragility, while careful preparation can enhance its strength without compromising its natural properties.

Article Abstract

Background: Although the porous hydroxyapatite (PHA) used in custom-made cranioplasty implants is a material appreciated for its biomimetic properties, before osteointegration it is initially very fragile. Nevertheless, we wondered whether this primary fragility is entirely due to brittleness or whether the surgeon's actions may influence the behavior of the material.

Methods: To study the influence of the surgeon's behavior, we made a virtual model of a custom-made PHA cranioplasty implant and submitted it to three implant procedural variables using finite element methods. In the first test, a scenario in which the surgeon's design, validation, and positioning techniques are impeccable, the edges of the implant adhered well to the craniectomy margins. In the second test, a discrepancy between a portion of the perimeter of the craniectomy and the profile of the prosthesis was modeled, and in the third test, several gaps were simulated between the implant and the craniectomy margins.

Results: Our mathematical model showed that when local and general discontinuities were included in the test scenarios, there was an increase in the load coming to bear on the cranioplasty implant, which amounted to 80 and 50 %, respectively.

Conclusions: The fragility of custom-made PHA cranioplasty implants increases if the surgeon fails to achieve a precise design and validation, and/or an accurate surgical procedure. Nevertheless, careful attention during these phases helps to maintain the strength of the implant, given the more favorable mechanical conditions, without interfering with its biomimetic capacity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00701-014-2319-yDOI Listing

Publication Analysis

Top Keywords

cranioplasty implants
12
porous hydroxyapatite
8
custom-made pha
8
pha cranioplasty
8
cranioplasty implant
8
design validation
8
implant
6
cranioplasty
5
spontaneous fractures
4
custom-made
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!