Statistical estimation of antibody concentration using multiple dilutions.

J Immunol Methods

Department of Infectious Disease Epidemiology, London School of Hygiene and Tropical Medicine, Keppel Street, WC1E 7HT London, UK.

Published: February 2015

In medicine and chemistry, measurement of concentrations usually involves calibration that maps the observed responses to the underlying concentration using inversion of a standard curve. The Enzyme-linked ImmunoSorbent Assay (ELISA) is one example of such methods that is commonly used to measure antibody concentration. A problem in this and similar type of technology is that an accurate measurement is obtainable only if the observations fall within the optimal, near-linear range of the standard curve. It is common to conduct a series of doubling or tripling dilutions of the samples, so that at least some of the diluted samples are within the optimal range. A single dilution may then be selected for statistical analysis. This common practice does not fully utilize the data from multiple dilutions and reduces accuracy. We consider two weighted average estimators for fully utilizing the information from multiple dilutions. The first uses weights inversely proportional to the variances of the dilution-specific calibrated values; the second is a simplified form of the first. Simulation results demonstrated the superiority of this weighted estimation approach over the conventional approach of analyzing a single selected dilution. We apply the methods to an experimental study of malaria vaccine candidates.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jim.2015.01.001DOI Listing

Publication Analysis

Top Keywords

multiple dilutions
12
antibody concentration
8
standard curve
8
statistical estimation
4
estimation antibody
4
concentration multiple
4
dilutions
4
dilutions medicine
4
medicine chemistry
4
chemistry measurement
4

Similar Publications

Tigecycline (Tgc), a third-generation tetracycline is found as the last line of defense against multi-drug resistant bacteria. Recent increased rate of resistance to tgc, a human-restricted agent among animal bacteria poses a significant global health challenge. Overuse of first generation tetracyclines (Tet) and phenicols in animals have been suggested to be associated with Tgc resistance development.

View Article and Find Full Text PDF

Background: Blood-based biomarkers, especially P-tau217, have been gaining interest as diagnostic tools to measure Alzheimer disease (AD) pathology.

Methods: We developed a plasma P-tau217 chemiluminescent immunoassay using 4G10E2 and IBA493 as antibodies, a synthetic tau peptide as calibrator, and the Quanterix SP-X imager. Analytical validation performed in a College of American Pathologists-accredited CLIA laboratory involved multiple kit lots, operators, timepoints, and imagers.

View Article and Find Full Text PDF

Background: Ripretinib, a broad-spectrum tyrosine kinase inhibitor, has been approved for the treatment of advanced gastrointestinal stromal tumors in adult patients. Clinical studies have shown that higher exposure of ripretinib correlates with improved efficacy, highlighting the potential clinical significance of therapeutic drug monitoring. In this study, a simple and stable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was attempted to be established and validated for pharmacokinetic studies of ripretinib and its metabolite DP-5439 and therapeutic drug monitoring in human plasma.

View Article and Find Full Text PDF

Background: Current guidelines recommend application of the 99th percentile to determine the cut-off value on at least 120 healthy donors regardless of sex for lupus anticoagulant (LA) ratio of each step. However, a statistically significant difference between the sexes has been found for LA ratio recently.

Objectives: To clarify whether this sex difference in dilute Russell's viper venom time (DRVVT) exists in various detection systems and the necessity of setting sex-specific cut-off values.

View Article and Find Full Text PDF

Rapid Determination of Water-Soluble Vitamins in Human Serum by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.

ACS Omega

January 2025

Clinical Nuclear Medicine Center, Imaging Clinical Medical Center, Institute of Nuclear Medicine, Institute of Clinical Mass Spectrometry Applied Research Center, Department of Nuclear Medicine, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai 200072, China.

Water-soluble vitamins play essential roles in normal body functions and metabolic activities. However, few methods have simultaneously measured all nine water-soluble vitamins in biological matrices. In this study, we developed a sensitive and accurate method for the simultaneous measurement of thiamine (B1), riboflavin (B2), nicotinamide (B3), pantothenic acid (B5), 4-pyridoxic acid (B6), biotin (B7), 5-methyltetrahydrofolic acid (B9), ascorbic acid (VC), and methylmalonic acid (MMA) in human serum.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!