The use of antiepileptic drugs increases the risk of major congenital malformations during pregnancy. Here, we report an infant who had a history of in-utero carbamazepine exposure and who was born with a cardiac malformation. The infant was born at 39 weeks of gestation vaginally to an epileptic mother who had been treated with carbamazepine throughout her pregnancy. He was referred due to cardiac murmur in the second week of his life. The mother had not received folic acid supplementation. Transthoracic echocardiography revealed bicuspid aortic valve, mild aortic stenosis, patent ductus arteriosus, patent foramen ovale and the renal ultrasound revealed mild left hydronephrosis. Follow-up echocardiography performed 14 weeks later showed increased severity of aortic stenosis and percutaneous balloon aortic valvuloplasty was performed. To our knowledge, there is only one case report in the literature mentioning the association of a bicuspid aortic valve and aortic stenosis with oxcarbazepine exposure, which is a structural derivative of carbamazepine. However, there are no reports for association with carbamazepine itself. Bicuspid aorta and aortic stenosis may be among the cardiac malformations that result from the teratogenic effect of carbamazepine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285218 | PMC |
http://dx.doi.org/10.5152/jtgga.2014.89577 | DOI Listing |
Eur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Heart Institute. Department of Cardiology. Cardiovascular Imaging Unit. Hospital Universitari Germans Trias i Pujol, Barcelona, Spain.
Aims: How the underlying etiology and pathophysiology of left ventricular (LV) hypertrophy affects LA remodeling and function remains unexplored. The present study aims to investigate the influence of various hypertrophic phenotypes on LA remodeling and function.
Methods And Results: Patients with LV hypertrophy who underwent cardiac magnetic resonance (CMR) were compared to a control group.
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!