North American contact dermatitis group patch test results: 2011-2012.

Dermatitis

From the University of Minnesota and the Minneapolis VAMC; University of California, San Francisco; Cleveland Clinic, Ohio; McGill University Health Centre, Montreal; University of Toronto, Canada; Ohio State University, Columbus; Associates in Dermatology, Fort Myers, Fla; Group Health Associates, Cincinnati, Ohio; Dartmouth Medical Center, Lebanon, NH; St. Luke's Roosevelt Hospital Center, New York, NY; Dermatology Specialists, Louisville, KY; Pennsylvania State University Hershey; University of Ottawa, Canada; Oregon Health Sciences University, Portland; and Columbia University Medical Center, New York, NY.

Published: September 2015

Background: Patch testing is an important diagnostic tool for assessment of allergic contact dermatitis (ACD).

Objective: This study documents the North American Contact Dermatitis Group (NACDG) patch-testing results from January 1, 2011, to December 31, 2012.

Methods: At 12 centers in North America, patients were tested in a standardized manner with a series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends analyzed using χ statistics.

Results: Four thousand two hundred thirty-eight patients were tested; of these, 2705 patients (63.8%) had at least 1 positive reaction, and 2029 (48.0%) were ultimately determined to have a primary diagnosis of ACD. Four hundred eight patients (9.6%) had occupationally related skin disease. There were 7532 positive allergic reactions. As compared with previous reporting periods (2009-2010 and 2000-2010), positive reaction rates statistically increased for 6 allergens: methylchloroisothiazolinone/methylisothiazolinone (5.0%; risk ratios [RRs]: 2.01 [1.60-2.52], 1.87 [1.61-2.18]), lanolin alcohol (4.6%; RRs 1.83 [1.45-2.30], 2.10 [1.79-2.47]), cinnamic aldehyde (3.9%; 1.69 [1.32-2.15], 1.53 [1.28-1.82]), glutaral (1.5%; 1.67 [1.13-2.48], 1.31 [1.00-1.71]), paraben mix (1.4%; 1.77 [1.16-2.69], 1.44 [1.09-1.92]), and fragrance mix I (12.1%; RRs 1.42 [1.25-1.61], 1.24 [1.14-1.36]). Compared with the previous decade, positivity rates for all formaldehyde-releasing preservatives significantly decreased (formaldehyde 6.6%; RR, 0.82 [0.73, 0.93]; quaternium-15 6.4% RR 0.75 [0.66, 0.85]; diazolidinyl urea 2.1%; RR, 0.67 [0.54, 0.84]; imidazolidinyl urea 1.6%, 0.60 [0.47, 0.77]; bronopol 1.6%; RR, 0.60 [0.46, 0.77]; DMDM hydantoin 1.6%; RR, 0.59 [0.54, 0.84]). Approximately a quarter of patients had at least 1 relevant allergic reaction to a non-NACDG allergen. In addition, approximately one-fourth to one-third of reactions detected by NACDG allergens would have been hypothetically missed by T.R.U.E. TEST (SmartPractice Denmark, Hillerød, Denmark).

Conclusions: These data document the beginning of the epidemic of sensitivity to methylisothiazolinones in North America, which has been well documented in Europe. Patch testing with allergens beyond a standard screening tray is necessary for complete evaluation of occupational and nonoccupational ACD.

Download full-text PDF

Source
http://dx.doi.org/10.1097/DER.0000000000000097DOI Listing

Publication Analysis

Top Keywords

contact dermatitis
12
north american
8
american contact
8
dermatitis group
8
patch testing
8
north america
8
patients tested
8
positive reaction
8
compared previous
8
[054 084]
8

Similar Publications

Background: Doxepin (DX) is used orally to relieve itching but can cause side effects like blurred vision, dry mouth, and drowsiness due to its antimuscarinic effect. To reduce these adverse effects and improve skin permeation, DX is being developed in topical formulations. This study aims to improve DX skin absorption by developing a microemulsion (ME) formulation (ME-DX).

View Article and Find Full Text PDF

Diaper Dermatitis Algorithm and Scoring Tool in the Neonatal Intensive Care Unit (NICU): A Quality Improvement Project.

J Wound Ostomy Continence Nurs

January 2025

Meredith Sharp, MSN, RN, CWON, MEDSURG-BC, Wound Ostomy Nurse Department, Oklahoma Children's Hospital at OU Health, Oklahoma City, Oklahoma.

Purpose: The purpose of this quality improvement project was to implement and evaluate an algorithm for management and prevention of diaper dermatitis (DD) embedded in a scoring tool. The specific aim of the project was to decrease DD occurrences with a severity score of 3 to 4 by 25%.

Participants And Setting: Quality improvement participants comprised 164 neonates; 89 were cared for prior to project implementation and 75 post-implementation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!