Introduction: We commonly use 6- and 4-clamped thermoplastic molds (TMs) for rigid immobilization during pelvic radiotherapy (RT), sometimes a vacuum cushion (VC) is also used as leg support with TM. Our objective was to report the setup margins (SMs) associated with the different systems, to analyze whether any of these systems is superior, and to analyze whether any of them showed better reproducibility in any particular direction.

Materials And Methods: Retrospective analysis was done by dividing the patients into four groups: 6-clamp with VC (6CVC), 6-clamp without VC (6CNC), 4-clamp with VC (4CVC), and 4-clamp without VC (4CNC). A repeat offline review was done for all patients and errors were tabulated. Statistical methods were then applied.

Results: Total 24 patients had 413 image-guided RT (IGRT) sessions, 312 were cone beam computed tomography scan (CBCT) scans and 101 were paired kilovoltage portals (kVp). There was no statistically significant difference between 6CVC and 6CNC. However, while comparing 4CVC and 4CNC, a statistically significant difference was seen in all directions. VC improved precision in vertical and lateral direction mainly, while the 6-clamped TM improved reproducibility in longitudinal direction.

Conclusions: SM was low for all the four immobilization systems studied. There is no added benefit of using a VC with 6-clamped TM for pelvic RT. Use of a VC is recommended with 4-clamped TM to improve overall reproducibility. 6-clamped TM helps keep the errors low.

Download full-text PDF

Source
http://dx.doi.org/10.4103/0973-1482.138026DOI Listing

Publication Analysis

Top Keywords

immobilization systems
8
paired kilovoltage
8
kilovoltage portals
8
statistically difference
8
comparison immobilization
4
systems
4
systems pelvic
4
pelvic radiation
4
radiation therapy
4
therapy cbct
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!