Alternative extrapulmonary oxygenation technologies are needed to treat patients suffering from severe hypoxemia refractory to mechanical ventilation. We previously demonstrated that peritoneal microbubble oxygenation (PMO), in which phospholipid-coated oxygen microbubbles (OMBs) are delivered into the peritoneal cavity, can successfully oxygenate rats suffering from a right pneumothorax. This study addressed the need to scale up the procedure to a larger animal with a splanchnic cardiac output similar to humans. Our results show that PMO therapy can double the survival time of rabbits experiencing complete tracheal occlusion from 6.6 ±0.6 min for the saline controls to 12.2 ±3.0 min for the bolus PMO-treated cohort. Additionally, we designed and tested a new peritoneal delivery system to circulate OMBs through the peritoneal cavity. Circulation achieved a similar survival benefit to bolus delivery under these conditions. Overall, these results support the feasibility of the PMO technology to provide extrapulmonary ventilation for rescue of severely hypoxic patients.