Safety of MR Imaging at 1.5 T in Fetuses: A Retrospective Case-Control Study of Birth Weights and the Effects of Acoustic Noise.

Radiology

From the Departments of Obstetrics and Gynecology (B.S., J.C.J., S.Z., T.C.), Radiology (E.M., M.M.C.), and Neurology (P.D.), University Hospital Brugmann, Place A. Van Gehuchten 4, 1020 Brussels, Belgium; Department of Radiology, University Hospitals Leuven, Leuven, Belgium (F.D.K.); Department of Pediatric Otorhinolaryngology, University Children's Hospital Reine Fabiola, Brussels, Belgium (I.P., A.L.M.); and Department of Radiology, UZ Brussel, Vrije Universiteit Brussels, Belgium (M.M.C.).

Published: May 2015

Purpose: To evaluate the effects of exposure to routine magnetic resonance (MR) imaging at 1.5 T during pregnancy on fetal growth and neonatal hearing function in relation to the dose and timing of in utero exposure in a group of newborns at low risk for congenital hearing impairment or deafness.

Materials And Methods: This retrospective case-control study was approved by the local ethics committee, and written informed consent was waived. Between January 2008 and December 2012, a group of 751 neonates exposed to MR imaging in utero and a group of control subjects comprising 10 042 nonexposed neonates, both groups with no risk factors for hearing impairment at birth, were included. Neonatal hearing screening was performed by means of otoacoustic emission testing and auditory brain stem response according to national guidelines, and the prevalence of hearing impairment in the two groups was compared by using a noninferiority test with Wilson score confidence intervals. The effect of MR exposure on birth weight percentile was examined between the singleton neonates in the exposed group and a randomly chosen subset of 1805 singleton newborns of the nonexposed group by performing an analysis of variance.

Results: The rate of hearing impairment or deafness was found to be 0% (0 of 751) in the neonates in the exposed group and was not inferior to that in the nonexposed group (34 of 10 042 [0.34%], P < .05). There was no between-group difference in birth weight percentiles (50.6% for exposed vs 48.4% for nonexposed; P = .22).

Conclusion: This study showed no adverse effects of exposure to 1.5-T MR imaging in utero on neonatal hearing function or birth weight percentiles.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.14141382DOI Listing

Publication Analysis

Top Keywords

hearing impairment
16
neonatal hearing
12
neonates exposed
12
birth weight
12
retrospective case-control
8
case-control study
8
effects exposure
8
hearing function
8
751 neonates
8
imaging utero
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!