Purpose: To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems.

Materials And Methods: Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%.

Results: The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected.

Conclusion: For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2014.11.012DOI Listing

Publication Analysis

Top Keywords

mandibular body
12
four-hole plate
12
plate screws
12
groups iii
12
locking fixation
8
simulated fractures
8
fractures mandibular
8
techniques brands
8
body fracture
8
fixed four-hole
8

Similar Publications

Aim: In this study, it was aimed to determine the changes in the anatomic structures of individuals with obstructive sleep apnea syndrome (OSAS) classified according to the apnea-hypopnea index (AHI).

Materials And Methods: Individuals were divided into groups as group 1 (AHI=0, n=20), group 2 (AHI ˂5, n=20), group 3 (AHI=5-15, n=20), group 4 (AHI=16-30, n=20), group 5 (AHI ˃30, n=20). The individuals left lateral cervical vertebra radiographs were taken.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Background: Medical simulation is relevant for training medical personnel in the delivery of medical and trauma care, with benefits including quantitative evaluation and increased patient safety through reduced need to train on patients.

Methods: This paper presents a prototype medical simulator focusing on ocular and craniofacial trauma (OCF), for training in management of facial and upper airway injuries. It consists of a physical, electromechanical representation of head and neck structures, including the mandible, maxillary region, neck, orbit and peri-orbital regions to replicate different craniofacial traumas.

View Article and Find Full Text PDF

Delayed inflammation after biodegradable and osteoconductive osteofixation in orthognathic surgery.

J Korean Assoc Oral Maxillofac Surg

December 2024

Department of Oral and Maxillofacial Surgery, College of Dentistry, Gangneung-Wonju National University, Gangneung, Korea.

Objectives: This study aims to identify patterns and to describe the clinical course of delayed adverse tissue responses in patients who underwent orthognathic osteotomy with biodegradable osteofixation.

Patients And Methods: Through a retrospective review of cases between 2013 and 2020, we identified three patients who underwent bimaxillary osteotomy and fixation with unsintered-hydroxyapatite/poly-L lactic acid (u-HA/PLLA) devices, after which they developed delayed inflammation. These lesions were treated with drainage and/or removal of the devices.

View Article and Find Full Text PDF

A 3-dimensional comparative assessment of the dentoskeletal effects of clear aligners vs temporary skeletal anchorage device-assisted posterior intrusion in adolescents with anterior open bite: A single-center, retrospective, cohort study.

Am J Orthod Dentofacial Orthop

December 2024

Discipline of Orthodontics, School of Dentistry, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia; Department of Orthodontics, Sydney Dental Hospital, Sydney Local Health District, Sydney, Australia; Division of Orthodontics, University Clinics of Dental Medicine, Faculty of Medicine, University of Geneva, Geneva, Switzerland. Electronic address:

Introduction: The dentoskeletal effects of clear aligner treatment (CAT) with Invisalign vs temporary skeletal anchorage device-anchored Sydney intrusion spring (SIS) were compared in consecutively treated growing patients with anterior open bite using cone-beam computed tomography scans.

Methods: Fifteen adolescents treated exclusively with Invisalign, and 14 with SIS (first-phase treatment) were assessed retrospectively. Rigid-wise, voxel-based registration of pretreatment and posttreatment cone-beam computed tomography scans were performed using the anterior cranial base, maxillary plane, and mandibular body as reference regions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!