Objective: The present study determined whether primary molar pulpotomies showed equal in vitro and clinical success when restored with sandwich restoration with a bulk-fill flowable composite (BFRBC) liner versus a stainless steel crown (SSC) restoration.
Study Design: Sixty extracted human primary second molars with proximo-occlusal cavities were selected for in vitro test. The specimens were randomly divided into three groups (n = 20) and restored with sandwich restoration with a BFRBC liner composite (RBC) restoration and SSC. In addition, sixty teeth were selected from 20 children and each child had at least three primary molars (first and/or second primary molar) requiring pulpotomy. The patients were recalled for clinical and radiographic evaluation at approximately 6- and 12-month intervals.
Results: The SSC restoration had significantly higher microleakage than the others. Although there was a significant difference between the RBC and the SSC (P = 0.02), the differences between the BFRBC and the RBC, as well as between the BFRBC and the SSC, were not statistically significant at the 12-month radiographic evaluation (P = 0.33 and P = 0.11, respectively).
Conclusion: In laboratory conditions, sandwich restoration with BFRBC liner showed a superior seal margins of pulpotomized primary molars. Based clinical and radiographical evaluation, teeth treated with formocresol pulpotomy and restored with sandwich restoration with BFRBC liner were as successful as those restored with a SSC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.17796/jcpd.38.4.f718041225w7621q | DOI Listing |
J Prosthet Dent
January 2025
Professor, Department of Ophthalmology, King George's Medical University, Lucknow, India.
Statement Of Problem: Clinical studies evaluating the levels of interleukin-1 beta (IL-1β) in tears and conjunctival secretions of patients with ocular defects after using ocular prostheses are lacking. Therefore, a comparative evaluation of IL-1β levels in the defective eye before and after placement of an ocular prosthesis is needed.
Purpose: The purpose of this clinical study was to compare the microbiota and IL-1β in tears and conjunctival secretions of patients with an ocular defect after using an ocular prosthesis.
Spectrochim Acta A Mol Biomol Spectrosc
January 2025
Zhejiang Cancer Hospital, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310022, PR China; School of Molecular Medicine, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310024, PR China.
J Mech Behav Biomed Mater
November 2024
The Second Rehabilitation Hospital of Shanghai, China; Engineering Research Center of Intelligent Rehabilitation for Traditional Chinese Medicine, Ministry of Education, School of Rehabilitation Science, Institute of Rehabilitation Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China. Electronic address:
Clinical cardiac patches exhibit unsatisfied biocompatibility, low adhesion, and inadequate compliance and suboptimal mechanical properties for cardiac disorders repair. To address these challenges, herein we have innovatively proposed a biomimetic nanofiber electrospun membrane with a sandwich structure strategy. The composite patch comprises a stretchable polyurethane (PU) as basic material, then infiltrated with biocompatible silk fibroin methacryloyl (Silk-MA) as the middle layer via electrospinning and finally covered with Bio-ILs (chemically modified biocompatible ionic liquids) to impart electrical conductivity.
View Article and Find Full Text PDFSci Rep
November 2024
Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Eye Institute, Gansu Road 4, Heping District, Tianjin, 300020, China.
This study aimed to describe a novel sandwich technique of minimally invasive surgical implantation by using corneal stromal lenticules for corneal perforation. This prospective observational study included nine patients aged 23-79 years (mean, 54 ± 9) from Tianjin Eye Hospital. Corneal stromal lenticules with a central thickness of 120 μm were obtained from small incision lenticule extraction(SMILE).
View Article and Find Full Text PDFAesthetic Plast Surg
November 2024
Department of Plastic Surgery, The Affiliated Friendship Plastic Surgery Hospital of Nanjing Medical University, Gulou District, No. 146, Hanzhong Road, Nanjing, 210029, Jiangsu Province, People's Republic of China.
Background: Lower facial asymmetry often results in an esthetically unpleasing appearance. The purpose of this study was to develop a novel method for correcting lower facial asymmetry using mandibular augmentation with sandwich bone grafts from the contralateral mandibular outer cortex (MOC), and to evaluate the efficacy of this method using computer-assisted techniques.
Methods: The medical records of 16 patients with lower facial asymmetry who underwent mandibular augmentation with sandwich bone grafts from the contralateral MOC between January 2016 and December 2019 were retrospectively reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!