A custom analog vector matrix multiplier (VMM) for a vestibular prosthesis is reported. The VMM functions to reduce misalignment between implanted angular rate sensors and associated peripheral sense organs and precompensate for spurious electrical stimulation of vestibular neurons. Operating in the CMOS subthreshold region, the VMM performs a 3-by-3 vector matrix multiplication of rate sensor outputs, magnitude <; ±250 mV, and bandwidth <; 1.25 kHz. To reduce susceptibility to device mismatches, time-division-multiplexed multiplication is employed requiring 727 μs for a complete operation cycle. Fabricated with TSMC 0.35 μm CMOS technology, the footprint is 1523 μm × 1548 μm and consumes 5.37 μW of power.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889307PMC
http://dx.doi.org/10.1109/EMBC.2014.6944996DOI Listing

Publication Analysis

Top Keywords

vestibular prosthesis
8
vector matrix
8
low-power time-division-multiplexed
4
time-division-multiplexed vector
4
vector matrix-multiplier
4
matrix-multiplier vestibular
4
prosthesis custom
4
custom analog
4
analog vector
4
matrix multiplier
4

Similar Publications

Excess cement and peri-implant disease: A cross-sectional clinical endoscopic study.

J Periodontol

January 2025

Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.

Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.

View Article and Find Full Text PDF

Vestibular Implant Surgery: How to Deal With Obstructed Semicircular Canals-A Diagnostic and Surgical Guide.

J Otolaryngol Head Neck Surg

January 2025

Division of Otorhinolaryngology-Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, University of Geneva, Geneva, Switzerland.

Background: A vestibular implant can partially restore vestibular function by providing motion information through implanted electrodes. During vestibular implantation, various obstructions of the semicircular canals, such as protein deposits, fibrosis, and ossification, can be encountered. The objective was to explore the relationship between preoperative imaging and intraoperative findings of semicircular canal obstruction and to develop surgical strategies for dealing with obstructions of the semicircular canal(s) in patients eligible for vestibular implantation.

View Article and Find Full Text PDF

The vestibular system is integral to behavior; the loss of peripheral vestibular function leads to disabling consequences, such as blurred vision, dizziness, and unstable posture, severely limiting activities of daily living. Fortunately, the vestibular system's well-defined peripheral structure and well-understood encoding strategies offer unique opportunities for developing sensory prostheses to restore vestibular function. While these devices show promising results in both animal models and implanted patients, substantial room for improvement remains.

View Article and Find Full Text PDF

Objective: To compare the utility of intraoperative electrically evoked auditory brainstem response (eABR) and electrically evoked stapedial reflex testing (eSRT) for cochlear nerve integrity monitoring during simultaneous translabyrinthine resection of vestibular schwannoma (VS) and cochlear implantation.

Study Design: Historical cohort study.

Setting: Tertiary academic referral center.

View Article and Find Full Text PDF

Audiometric results of tympanoplasty with stapedectomy and synthetic total ossicular replacement prosthesis: A STROBE analysis.

Eur Ann Otorhinolaryngol Head Neck Dis

December 2024

Service d'ORL et de chirurgie cervico-faciale, centre hospitalo-universitaire, Dijon, France; Laboratoire ICMUB, UMR CNRS 6302, université de Bourgogne, Dijon, France.

Aim: To evaluate the audiometric results of tympanoplasty with stapedectomy and insertion of a synthetic total ossicular replacement prosthesis (TORP).

Material And Methods: Retrospective observational study conducted on a cohort of 15 patients (16 ears) aged 10 to 58 years (mean: 36 years) with chronic otitis media (COM) and tympanosclerosis (n=9), stapediovestibular ankylosis (n=3), minor aplasia (n=3) or post-traumatic ossicular dislocation (n=1). Treatment consisted in tympanoplasty with stapedectomy and TORP placement by the same operator, between December 1, 2012 and January 30, 2023, in a French university hospital department, with follow-up ranging from 2 to 92 months (mean: 24 months).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!