Determining locations of focal arrhythmia sources and quantifying myocardial conduction velocity (CV) are two major challenges in clinical catheter ablation cases. CV, wave-front direction and focal source location can be estimated from multipolar catheter data, but currently available methods are time-consuming, limited to specific electrode configurations, and can be inaccurate. We developed automated algorithms to rapidly identify CV from multipolar catheter data with any arrangement of electrodes, whilst providing estimates of wavefront direction and focal source position, which can guide the catheter towards a focal arrhythmic source. We validated our methods using simulations on realistic human left atrial geometry. We subsequently applied them to clinically-acquired intracardiac electrogram data, where CV and wavefront direction were accurately determined in all cases, whilst focal source locations were correctly identified in 2/3 cases. Our novel automated algorithms can potentially be used to guide ablation of focal arrhythmias in real-time in cardiac catheter laboratories.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2014.6943906DOI Listing

Publication Analysis

Top Keywords

wavefront direction
12
multipolar catheter
12
focal source
12
conduction velocity
8
direction focal
8
catheter data
8
automated algorithms
8
focal
7
catheter
6
automated algorithm
4

Similar Publications

Helical Surface Relief Formation by Two-Photon Polymerization Reaction Using a Femtosecond Optical Vortex Beam.

J Phys Chem Lett

January 2025

Department of Chemistry, Graduate School of Science, Osaka Metropolitan University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585, Japan.

Optical vortices possess a helical phase wavefront with central phase dislocation and orbital angular momentum. We demonstrated three-dimensional microstructure formation using a femtosecond optical vortex beam. Two-photon polymerization of photocurable resin was induced by long-term exposure, resulting in the fabrication of cylindrical structures.

View Article and Find Full Text PDF

A core framework of the gene regulatory network (GRN) governing neural crest (NC) cell development has been generated by integrating separate inputs from diverse model organisms rather than direct comparison. This has limited insights into the diversity of genes in the NC cell GRN and extent of conservation of newly identified transcriptional signatures in cell differentiation and invasion. Here, we address this by leveraging the strengths and accessibility of the avian embryo to precise developmental staging by egg incubation and use an integrated analysis of chick (HH13) and mouse (E9.

View Article and Find Full Text PDF

Elucidating subcellular architecture and dynamics at isotropic 100-nm resolution with 4Pi-SIM.

Nat Methods

December 2024

Westlake Laboratory of Life Sciences and Biomedicine, Hangzhou, China.

Article Synopsis
  • 3D-SIM improves image resolution in all dimensions but struggles with axial resolution, causing blurriness and distortion.
  • 4Pi-SIM combines 3D-SIM with interferometric techniques, enhancing optical resolution and allowing for clearer imaging of subcellular structures across various cell types.
  • This advanced imaging method enables high-resolution, time-lapse volumetric analysis and two-color imaging, revealing intricate cellular interactions and fine details at the nanoscale.
View Article and Find Full Text PDF

To overcome the limitations of phase sampling points in testing aspherical surface wavefronts using traditional interferometers, we propose a high-spatial-resolution method based on multi-directional orthogonal lateral shearing interferometry. In this study, we provide a detailed description of the methodology, which includes the theoretical foundations and experimental setup, along with the results from simulations and experiments. By establishing a relational model between the multi-directional differential wavefront and differential Zernike polynomials, we demonstrate high-spatial-resolution wavefront reconstruction using multi-directional orthogonal lateral shearing interferometry.

View Article and Find Full Text PDF

Corneal cross-linking.

Prog Retin Eye Res

January 2025

ELZA Institute, Webereistrasse 2, CH-8953, Dietikon, Switzerland; Laboratory for Ocular Cell Biology, University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland; Faculty of Medicine, University of Geneva, Rue Michel-Servet 1, CH-1206, Geneva, Switzerland. Electronic address:

First introduced over 20 years ago as a treatment for progressive keratoconus, the original "Dresden" corneal cross-linking (CXL) protocol involved riboflavin saturation of the stroma, followed by 30 min of 3 mW/cm-intensity ultraviolet-A (UV-A) irradiation. This procedure generates reactive oxygen species (ROS) that cross-link stromal molecules, thereby stiffening the cornea and counteracting the ectasia-induced weakening. Due to their large size, riboflavin molecules cannot readily pass through the corneal epithelial cell tight junctions; thus, epithelial debridement was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!