Artefact detection in neonatal EEG.

Annu Int Conf IEEE Eng Med Biol Soc

Published: October 2016

Artefact detection is an important component of any automated EEG analysis. It is of particular importance in analyses such as sleep state detection and EEG grading where there is no null state. We propose a general artefact detection system (GADS) based on the analysis of the neonatal EEG. This system aims to detect both major and minor artefacts (a distinction based primarily on amplitude). As a result, a two-stage system was constructed based on 14 features extracted from EEG epochs at multiple time scales: [2, 4, 16, 32]s. These features were combined in a support vector machine (SVM) in order to determine the presence of absence of artefact. The performance of the GADS was estimated using a leave-one-out cross-validation applied to a database of hour long recordings from 51 neonates. The median AUC was 1.00 (IQR: 0.95-1.00) for the detection of major artefacts and 0.89 (IQR: 0.83-0.95) for the detection of minor artefacts.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2014.6943743DOI Listing

Publication Analysis

Top Keywords

artefact detection
12
neonatal eeg
8
minor artefacts
8
eeg
5
detection
5
artefact
4
detection neonatal
4
eeg artefact
4
detection component
4
component automated
4

Similar Publications

Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.

View Article and Find Full Text PDF

Comparisons of integrated slice-specific dynamic shimming EPI and single-shot EPI diffusion-weighted imaging of the liver.

Eur J Radiol

January 2025

Department of Radiology, The Second Xiangya Hospital, Central South University, No.139 Middle Renmin Road, Changsha, Hunan, 410011, China; Department of Radiology Quality Control Center, Changsha, Hunan Province, 410011, China; The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Institute of Health and Rehabilitation Science, Xi'an Jiaotong University, Xi'an 710049,China. Electronic address:

Purpose: To compare the quality of DWI images, signal loss of left hepatic lobe and diagnostic performance of apparent diffusion coefficient (ADC) values between SS-EPI and iShim-EPI in liver lesions.

Methods: Totally 142 patients were involved, images using SS-EPI and the prototype iShim-EPI were acquired before injection of gadoxetic acid-enhanced liver MRI.Image quality of demarcation of liver capsule, resolution, lesion distortion, artifacts, lesion confidence score, and signal loss in left hepatic lobe was assessed by two radiologists.

View Article and Find Full Text PDF

Determination of the Time-frequency Features for Impulse Components in EEG Signals.

Neuroinformatics

January 2025

Institute of Mathematics, University of Kassel, Heinrich-Plett-Str. 40, Kassel, 34132, Germany.

Accurately identifying the timing and frequency characteristics of impulse components in EEG signals is essential but limited by the Heisenberg uncertainty principle. Inspired by the visual system's ability to identify objects and their locations, we propose a new method that integrates a visual system model with wavelet analysis to calculate both time and frequency features of local impulses in EEG signals. We develop a mathematical model based on invariant pattern recognition by the visual system, combined with wavelet analysis using Krawtchouk functions as the mother wavelet.

View Article and Find Full Text PDF

Measuring the effects of motion corruption in fetal fMRI.

Hum Brain Mapp

February 2025

Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.

Irregular and unpredictable fetal movement is the most common cause of artifacts in in utero functional magnetic resonance imaging (fMRI), affecting analysis and limiting our understanding of early functional brain development. The accurate detection of corrupted functional connectivity (FC) resulting from motion artifacts or preprocessing, instead of neural activity, is a prerequisite for reliable and valid analysis of FC and early brain development. Approaches to address this problem in adult data are of limited utility in fetal fMRI.

View Article and Find Full Text PDF

Cryopreservation of brain cell structure: a review.

Free Neuropathol

January 2024

Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA.

Cryopreservation, the preservation of tissues at subzero temperatures, is a mainstay of brain banking that allows for the storage of brain tissue without the use of chemical fixatives. This is particularly important for molecular studies that are incompatible with tissue fixation. However, brain tissue is vulnerable to various forms of damage during the cryopreservation process, in particular due to the phase transition of water from a liquid to a solid state with the formation of ice crystals, which can disrupt cellular morphology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!