The static magnetic field generated by MRI systems is highly non-homogenous and rapidly decreases when moving away from the bore of the scanner. Consequently, the movement around the MRI scanner is equivalent to an exposure to a time-varying magnetic field at very low frequency (few Hz). If people with an implanted pacemaker (PM) enter the MRI room, fast movements may thus induce voltages on the loop formed by the PM lead, with the potential to modify the correct behavior of the stimulator. In this study, we performed in-vitro measurements on a human-shaped phantom, equipped with an implantable PM and with a current sensor, able to monitor the activity of the PM while moving the phantom in the MRI room. Fast rotational movements in close proximity of the bore of the scanner caused the inappropriate inhibition of the PM, programmed in VVI modality, maximum sensitivity, unipolar sensing and pacing. The inhibition occurred for a variation of the magnetic field of about 3 T/s. These findings demonstrate that great care must be paid when extending PM MRI compatibility from patients to healthcare personnel, since the safety procedures and the MRI-conditional PM programming (e.g. asynchronous stimulation or bipolar sensing) used for patients cannot be applied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2014.6943734 | DOI Listing |
Oper Neurosurg (Hagerstown)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.
View Article and Find Full Text PDFJ Neurol Surg B Skull Base
February 2025
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, United States.
The abducens nerve has a long, serpentine subarachnoid course with complex topographical relationships, rendering abducens nerve palsy the most common ocular motor cranial nerve palsy in adults and second most common in pediatric patients, with anatomical variants reported in the literature. Preoperative awareness of abducens nerve variant anatomy may help prevent inadvertent intraoperative injury. This study is a case report with a review of the abducens nerve anatomy and variants.
View Article and Find Full Text PDFProg Neuropsychopharmacol Biol Psychiatry
January 2025
Institute of Brain Science, National Yang-Ming Chiao Tung University, Taipei 11221, Taiwan; Brain Research Center, National Yang-Ming Chiao Tung University, Taipei 11221, Taiwan; Digital Medicine and Smart Healthcare Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan; Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan. Electronic address:
While the etiology of schizophrenia (SZ) remains elusive, its diverse phenotypes suggest the involvement of distinct functional cortical areas, and the heritability of SZ implies the underlying genetic factors. This study aimed to integrate imaging and molecular analyses to elucidate the genetic underpinnings of SZ. We investigated the local cortical structural pattern changes in Brodmann areas (BAs) by calculating the cortical structural pattern index (SPI) using magnetic resonance imaging analysis from 194 individuals with SZ and 330 controls.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Aerospace Engineering Department and Interdisciplinary Research Center for Smart Mobility and Logistics, and Interdisciplinary Research Center Aviation and Space Exploration, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
Artificial intelligence (AI) has recently made unprecedented contributions in every walk of life, but it has not been able to work its way into diagnostic medicine and standard clinical practice yet. Although data scientists, researchers, and medical experts have been working in the direction of designing and developing computer aided diagnosis (CAD) tools to serve as assistants to doctors, their large-scale adoption and integration into the healthcare system still seems far-fetched. Diagnostic radiology is no exception.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Radiology, University of California San Diego, San Diego, CA 92037, USA.
It is known that ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences can detect signals from water protons but not collagen protons in short T2 species such as cortical bone and tendons. However, whether collagen protons are visible with the zero echo time (ZTE) MRI sequence is still unclear. In this study, we investigated the potential of the ZTE MRI sequence on a clinical 3T scanner to directly image collagen protons via DO exchange and freeze-drying experiments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!