A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improved automated optic cup segmentation based on detection of blood vessel bends in retinal fundus images. | LitMetric

Glaucoma is a leading cause of permanent blindness. Retinal imaging is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, ophthalmologists may determine the cup and disc areas and diagnose glaucoma using a vertical optic cup-to-disc (C/D) ratio and a rim-to-disc (R/D) ratio. Previously we proposed a method to determine cup edge by analyzing a vertical profile of pixel values, but this method provided a cup edge smaller than that of an ophthalmologist. This paper describes an improved method using the locations of the blood vessel bends. The blood vessels were detected by a concentration feature determined from the density gradient. The blood vessel bends were detected by tracking the blood vessels from the disc edge to the primary cup edge, which was determined by our previous method. Lastly, the vertical C/D ratio and the R/D ratio were calculated. Using forty-four images, including 32 glaucoma images, the AUCs of both the vertical C/D ratio and R/D ratio by this proposed method were 0.966 and 0.936, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2014.6943545DOI Listing

Publication Analysis

Top Keywords

blood vessel
12
vessel bends
12
c/d ratio
12
r/d ratio
12
cup edge
12
determine cup
8
ratio proposed
8
proposed method
8
blood vessels
8
vertical c/d
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!