A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Does electrocautery damage cochlear implants? | LitMetric

Objectives: 1) Evaluate the effects of monopolar cautery on cochlear implant devices. 2) Determine whether voltage fluctuations within the cochlear implant adversely affect the cochlear implant devices

Study Design: Two Med-El cochlear implants modified to record voltage difference from the apical and proximal electrodes were implanted into an unembalmed, fresh cadaver. Cautery was applied to the ipsilateral pectoralis major muscle and ipsilateral temporalis muscle at bipolar, monopolar coagulation, and monopolar cut settings of 50 W. The intensity in each modality setting was increased by increments of 10 W to a maximum of 100 W. Integrity testing was performed before, during, and after each cautery setting. Voltage fluctuations were measured during cautery, and maximal voltage changes for each setting were noted. After explantation, devices were returned to the manufacturer for in-depth failure analysis to evaluate for any damage to the devices.

Setting: Tertiary medical center.

Subjects: Cadaveric study.

Methods: Basic science laboratory.

Results: No change in impedance or integrity testing occurred at any cautery setting when applied to either to pectoralis major or temporalis. The maximum voltage change was 22 V. Comprehensive device analysis showed no evidence of device damage from the study.

Conclusions: The cochlear implant devices had no evidence of electrical damage by monopolar cautery, even up to levels of 100 W in the temporalis muscle. The maximum voltage change was 22 V, likely resulting from protecting diodes within the implant. Additional study is necessary, but more flexible recommendations regarding electrosurgery in cochlear implant recipients should be considered.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000000701DOI Listing

Publication Analysis

Top Keywords

cochlear implant
20
monopolar cautery
8
implant devices
8
voltage fluctuations
8
pectoralis major
8
temporalis muscle
8
integrity testing
8
cautery setting
8
maximum voltage
8
voltage change
8