A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Home monitoring of implantable cardioverter-defibrillators: interpretation reliability of the second-generation "IEGM Online" system. | LitMetric

Aims: Intracardiac electrograms (IEGMs) are essential for the assessment of implantable cardioverter-defibrillator (ICD) function. The Biotronik Home Monitoring systems transmit an 'IEGM Online' that is shorter than the full-length programmer IEGM due to technical constrains. The aim of this study was to evaluate the accuracy of the physician's classification of the underlying rhythm based on the second-generation IEGM Online.

Methods And Results: In total, 1533 patients treated with single- and dual-chamber ICDs and cardiac resynchronization therapy defibrillators were enrolled at 67 investigational sites and followed for 15 months. The investigators classified the rhythm shown in IEGM Online as ventricular tachycardia, ventricular fibrillation, atrial fibrillation, other supraventricular tachyarrhythmia, oversensing due to lead failure, T-wave oversensing, or other rhythm. At the next in-office follow-up, the investigators classified independently the rhythm seen in the corresponding programmer IEGM. The two rhythm classifications were compared thereafter. Both IEGM Online and programmer IEGM were available in 2099 arrhythmic or oversensing events, of which 146 (7.0%) were classified as other rhythm or artefacts and were excluded as inconclusive or atypical. The remaining 1953 events, affecting 352 patients (23.0%), were classified correctly in 1803 cases (92.3%). The accuracy of rough rhythm classification as ventricular, supraventricular, or oversensing was 97.2%.

Conclusion: The Lumax and IEGM Online HD Evaluation study demonstrates that remote IEGM analysis is reasonably accurate in a remote monitoring system that transmits shorter IEGM than the full-length programmer IEGM for the sake of frequent, fully automatic data transmission.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4381835PMC
http://dx.doi.org/10.1093/europace/euu349DOI Listing

Publication Analysis

Top Keywords

programmer iegm
16
iegm online
12
iegm
10
full-length programmer
8
investigators classified
8
classified rhythm
8
rhythm
7
monitoring implantable
4
implantable cardioverter-defibrillators
4
cardioverter-defibrillators interpretation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!