Background: The sedation needs of critically ill patients have been recognized as a core component of critical care and meeting these is vital to assist recovery and ensure humane treatment. There is growing evidence to suggest that sedation requirements are not always optimally managed. Sub-optimal sedation incorporates both under- and over-sedation and has been linked to both short-term (e.g. length of stay) and long-term (e.g. psychological recovery) outcomes. Various strategies have been proposed to improve sedation management and address aspects of assessment as well as delivery of sedation.
Objectives: To assess the effects of protocol-directed sedation management on the duration of mechanical ventilation and other relevant patient outcomes in mechanically ventilated intensive care unit (ICU) patients. We looked at various outcomes and examined the role of bias in order to examine the level of evidence for this intervention.
Search Methods: We searched the Cochrane Central Register of Controlled trials (CENTRAL) (2013; Issue 11), MEDLINE (OvidSP) (1990 to November 2013), EMBASE (OvidSP) (1990 to November 2013), CINAHL (BIREME host) (1990 to November 2013), Database of Abstracts of Reviews of Effects (DARE) (1990 to November 2013), LILACS (1990 to November 2013), Current Controlled Trials and US National Institutes of Health Clinical Research Studies (1990 to November 2013), and reference lists of articles. We re-ran the search in October 2014. We will deal with any studies of interest when we update the review.
Selection Criteria: We included randomized controlled trials (RCTs) conducted in adult ICUs comparing management with and without protocol-directed sedation.
Data Collection And Analysis: Two authors screened the titles and abstracts and then the full-text reports identified from our electronic search. We assessed seven domains of potential risk of bias for the included studies. We examined the clinical, methodological and statistical heterogeneity and used the random-effects model for meta-analysis where we considered it appropriate. We calculated the mean difference (MD) for duration of mechanical ventilation and risk ratio (RR) for mortality across studies, with 95% confidence intervals (CI).
Main Results: We identified two eligible studies with 633 participants. Both included studies compared the use of protocol-directed sedation, specifically protocols delivered by nurses, with usual care. We rated the risk of selection bias due to random sequence generation low for one study and unclear for one study. The risk of selection bias related to allocation concealment was low for both studies. We also assessed detection and attrition bias as low for both studies while we considered performance bias high due to the inability to blind participants and clinicians in both studies. Risk due to other sources of bias, such as potential for contamination between groups and reporting bias, was considered unclear. There was no clear evidence of differences in duration of mechanical ventilation (MD -5.74 hours, 95% CI -62.01 to 50.53, low quality evidence), ICU length of stay (MD -0.62 days, 95% CI -2.97 to 1.73) and hospital length of stay (MD -3.78 days, 95% CI -8.54 to 0.97) between people being managed with protocol-directed sedation versus usual care. Similarly, there was no clear evidence of difference in hospital mortality between the two groups (RR 0.96, 95% CI 0.71 to 1.31, low quality evidence). ICU mortality was only reported in one study preventing pooling of data. There was no clear evidence of difference in the incidence of tracheostomy (RR 0.77, 95% CI 0.31 to 1.89). The studies reported few adverse event outcomes; one study reported self extubation while the other study reported re-intubation; given this difference in outcomes, pooling of data was not possible. There was significant heterogeneity between studies for duration of mechanical ventilation (I(2) = 86%, P value = 0.008), ICU length of stay (I(2) = 82%, P value = 0.02) and incidence of tracheostomy (I(2) = 76%, P value = 0.04), with one study finding a reduction in duration of mechanical ventilation and incidence of tracheostomy and the other study finding no difference.
Authors' Conclusions: There is currently insufficient evidence to evaluate the effectiveness of protocol-directed sedation. Results from the two RCTs were conflicting, resulting in the quality of the body of evidence as a whole being assessed as low. Further studies, taking into account contextual and clinician characteristics in different ICU environments, are necessary to inform future practice. Methodological strategies to reduce the risk of bias need to be considered in future studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/14651858.CD009771.pub2 | DOI Listing |
Pediatr Cardiol
January 2025
Pediatric Intensive Care Department, Wolfson Medical Center, Holon, Israel.
Research establishing factors associated with duration of mechanical ventilation after Tetralogy of Fallot repair, is mainly based on population presenting at early infancy. There are fewer reports regarding repair after infancy, during childhood and preadolescence. To compare two groups of late TOF repair based on post-operative invasive mechanical ventilation duration and explore associations with pre-operative clinical markers of severity of right ventricular outflow tract obstruction.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:
Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.
Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.
J Hazard Mater
January 2025
School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
The toxic fume emitted from asphalt pavement remains a health and environmental hazard towards public safety, especially the emission of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs). Despite extensive studies focused on characterizing asphalt fumes generated during construction stages (i.e.
View Article and Find Full Text PDFCrit Care Sci
January 2025
Health Economics, Hospital Management and Nursing Research Deptment, School of Public Health, Université Libre de Bruxelles - Bruxelles, Belgium.
Objective: This study aimed to explore the association between high outliers and intensive care unit admissions and to identify the factors contributing to high intensive care unit costs.
Methods: This retrospective cohort study used data from 17 Belgian hospitals from 2018 and 2019. The study focused on the 10 most frequently admitted diagnosis-related groups in the intensive care unit.
Crit Care Sci
January 2025
Anaesthesiology and Critical Care, All India Institute of Medical Sciences - Jodhpur, India.
Objective: Although the efficacy of high-flow nasal oxygen therapy in delaying or avoiding intubation in patients with hypoxemic respiratory failure has been studied, its potential for facilitating early weaning from invasive mechanical ventilation remains unexplored.
Methods: In this randomized controlled trial, 80 adults with acute hypoxemic respiratory failure requiring invasive mechanical ventilation for > 48 hours were enrolled and divided into two groups: conventional weaning and early weaning via high-flow nasal oxygen. In the conventional weaning group, the spontaneous breathing trial was performed after the PaO2/FiO2 ratio was ≥ 200, whereas in the high-flow nasal oxygen group, the spontaneous breathing trial was conducted earlier when the PaO2/FiO2 ratio was 150 - 200.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!