Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Non-muscle invasive bladder cancer can be missed during white light endoscopy in up to 50% of cases. We aimed to test whether or not we could find a difference between benign and cancerous tissue wavelengths using laser induced autofluorescence spectroscopy can increase cancer detection.
Materials And Methods: We analysed 67 tissue samples using spectral analysis. The WavSTAT (Spectra Science) optical biopsy device was used to record fluorescence spectra from biopsied tissue enabling calculation of an AUC for each spectrum, a measure of the mean spectral wavelength (λ¯ (nm)) and a dimensionless fluorescence ratio. Mann-Whitney test was used to compare the two groups.
Results: We found that 49.3% (33/67) of the tissue was benign, 44.8% (30/67) was CIS/cancerous tissue, and the remaining 4/67 samples were atypia (2) and dysplasia (2). The median AUC for the benign tissue was 19.53 (interquartile range [IQR]: 5.35-30.39) and that for CIS/cancerous tissue was 7.05 (IQR: 2.89-14.24) (P=0.002). The median wavelengths for the benign tissue and malignant tissue were 502.4nm (IQR: 500.3-504.3nm) and 505.2nm (IQR: 502.1-513.2nm), respectively (P=0.003). The median fluorescence ratio was 0.080 (IQR: 0.070-0.088) for benign tissue and 0.096 (IQR: 0.079-0.221) for CIS/cancerous tissue (P=0.002).
Conclusions: We found statistical differences between the median AUC calculations and median wavelengths for the benign and cancerous tissue. We also found a statistical difference between the fluorescence ratios between the two tissue types. There seems to be a role for optical spectroscopy in verifying bladder lesions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pdpdt.2014.12.003 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!