Unlabelled: Risk assessment for upper extremity work related muscoloskeletal disorders by applying six methods of ergonomic: a ten years experience. The objective of this research was to verify and validate the multiple step method suggested by SIMLII guidelines and to compare results obtained by use of these methods: Washington State Standard, OCRA, HAL, RULA, OREGE and STRAIN INDEX.
Methods: 598 workstations for a total of 1800 analysis by different methods were considered, by adopting the following multiple step procedure: prelinminary evaluation by Washington State method and OCRA checklist in all the working stations, RULA or HAL as first level evaluation, OREGE or SI as second level evaluation.
Results: The preliminary evaluation resulted negative (risk absent) in the 75% of examined work stations and by using checklist OCRA optimal-acceptable condition was found in 58% by HAL in 92% of analysis, by RULA in 100%, by OREGE in 64%; by SI in 70% of examined working positions. We observed similar evaluation of strain among methods and main differences have been observed in posture and frequency assessment.
Discussion And Conclusion: The preliminary evaluation by State of Washington method appears to be an adequate instrument for identify the working condition at risk. All the adopted methods were in a good agreement in two estreme situations: high risk or absent risk, expecially in absent risk conditions. Level of accordance varied on the basis of their rationale and of the role of their different components so SIML indications about the critical use of biouzechanical methods and about the possible use of more than one of them (considering working chlaracteristics) have been confirmed.
Download full-text PDF |
Source |
---|
Animal
September 2024
Department of Animal Science and Aquaculture, Dalhousie University, Truro, Nova Scotia B2N 5E3, Canada. Electronic address:
The feed efficiency (FE) expresses as the amount of feed required per unit of BW gain. Since feed cost is the major input cost in the mink industry, evaluating of FE is a crucial step for competitiveness of the mink industry. However, the FE measures have not been widely adopted for the mink due to the high cost of periodically measuring BW and daily feed intake.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Biomedical and Neuromotor Sciences, Bologna University, Piazza di Porta S. Donato St 2, 40-127, Bologna, Italy.
Objectives: The purpose of this study was to propose a new difficulty score for the treatment of multiple gingival recessions (GRs) with Modified Coronally Advanced Tunnel (MCAT), and to test the score's reliability.
Material And Methods: A difficulty score was developed for the assessment and grading of 13 relevant anatomical parameters at baseline. Six experienced dental practitioners evaluated existing GRs in three patients.
Foot Ankle Int
January 2025
Foot and Ankle Surgery Department, Honghui Hospital of Xi'an Jiaotong University, Xi'an, China.
Background: Calcaneal fracture malunion (CFM) commonly occurs with multiple pathologic changes and progressive pain and difficulty walking. The purpose of this study was to propose a modified 3-plane joint-preserving osteotomy for the treatment of CFM with subtalar joint incongruence, and to compare its efficacy to subtalar arthrodesis.
Methods: A retrospective comparative analysis of the data of 56 patients with CFM admitted from January 2017 to December 2022 was performed.
Pharmaceutics
January 2025
Department of Chemical and Pharmaceutical Sciences, University of Trieste, Piazzale Europa 1, 34127 Trieste, Italy.
This study investigates the preparation of coamorphous systems composed entirely of active pharmaceutical ingredients (APIs), namely praziquantel, niclosamide, and mebendazole. The objective was to formulate and characterize binary and ternary coamorphous systems to evaluate their structural, thermal, and stability properties. Ten different mixtures (binary and ternary) were designed through a mixture design approach and prepared using a sustainable, one-step neat grinding process in a lab-scale vibrational mill.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Shunde Innovation School, University of Science and Technology Beijing, Foshan 528399, China.
Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!