Background/aim: To determine whether plasma sclerostin levels are affected by applying whole-body vibration treatments.
Materials And Methods: Following a pilot study, the pretsent prospective, randomized, controlled single-blind study was performed on 16 healthy volunteer women (ages 20 to 40 years). Subjects were randomly divided into 2 groups, and whole-body vibration was applied to the treatment group but not to the controls. The plasma sclerostin levels were measured before the treatment and at the 10th minute after whole-body vibration on the 1st, 2nd, and 5th days of application.
Results: The plasma sclerostin level measured at 10 min after the whole-body vibration treatment increased 91% (P = 0.024) on the 1st day and decreased 31.5% (P = 0.03) on the 5th day in the whole-body vibration group. In the control group, there was no change in the plasma sclerostin level at any time. A progressive increase in baseline plasma sclerostin levels during the 5 days of vibration sessions was also found.
Conclusion: Our study demonstrated that whole-body vibration can change plasma sclerostin levels, and that this change is detectable 10 min after whole-body vibration treatments.