Bead-based suspension array for simultaneous differential detection of five major swine viruses.

Appl Microbiol Biotechnol

Animal Inspection and Quarantine Laboratory, Technical Center, Guangdong Entry-Exit Inspection and Quarantine Bureau, No.66 Huacheng Dadao Ave., Zhujiangxincheng, Guangzhou, 510623, China,

Published: January 2015

A novel multiplex detection array based on Luminex xMAP technology was developed and validated for simultaneous detection of five major viruses causing swine reproductive diseases. By combining one-step asymmetric multiplex reverse transcription polymerase chain reaction (RT-PCR) with xMAP bead-based hybridization and flow cytometry analysis, the resulting multiplex assay was capable of detecting single and mixed infections of PRRSV, PCV-2, PRV, CSFV, and PPV in a single reaction. The assay accurately detected and differentiated 23 viral strains used in this study. The low detection limit was determined as 2.2-22 copies/μL (corresponding to 0.5-6.8 fg/μL DNA template) on plasmid constructs containing viral fragments. The intra-assay and inter-assay variances (CV%) were low that ranged from 2.5 to 5.4 % and 4.1 to 7.6 %, respectively. The assay was applied to test field samples and detected single and mixed viral infections. The detection rate was higher than that of uniplex conventional PCR and RT-PCR methods. The detection of PRRSV by the bead-based multiplex assay was comparable with a commercially available real time RT-PCR kit. The test procedure on purified DNA or RNA samples could be completed within 2 h. In conclusion, the bead-based suspension array presented here proved to be a high-throughput practical tool that provided highly specific and sensitive identification of single and multiple infections of five major viruses in pigs and boar semen.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00253-014-6337-8DOI Listing

Publication Analysis

Top Keywords

bead-based suspension
8
suspension array
8
detection major
8
major viruses
8
multiplex assay
8
single mixed
8
detection
6
bead-based
4
array simultaneous
4
simultaneous differential
4

Similar Publications

Canine mammary tumor (CMT) is a prevalent and destructive disease often diagnosed at an advanced stage, leading to poor outcomes. Currently, there is a lack of effective biomarkers for early detection and prognostic prediction of CMT. To improve CMT detection, we established a multiplexed immunoassay using a fluorescence bead-based suspension array system to measure serum levels of autoantibodies against four CMT-associated proteins (AGR2, HAPLN1, IGFBP5, and TYMS) in CMT patients.

View Article and Find Full Text PDF

Bead-based spontaneous Raman codes for multiplex immunoassay.

Anal Chim Acta

August 2024

Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, and Chemical Biology Center, College of Chemistry, Central China Normal University, Wuhan, 430079, Hubei, China. Electronic address:

In the immunoassay process, for fulfilling the need to identify multiple analytes in a small amount of complex sample matrix, it is desirable to develop highly efficient and specific multiplex suspension array technology. Raman coding strategy offers an attractive solution to code the suspension arrays by simply combing narrow spectral bands with stable signal intensities through solid-phase synthesis on the resin beads. Based on this strategy, we report the bead-based spontaneous Raman codes for multiplex immunoassay.

View Article and Find Full Text PDF

Purpose: Periprosthetic joint infections (PJIs) are a very demanding complication of arthroplasty. Diagnosis of PJI and pathogen identification pose considerable challenges in clinical practice. We hypothesized that the pathogen-specific immune response to PJI reflects the infection process, provides clinically relevant information on disease course, and has the potential to further optimize antimicrobial therapy.

View Article and Find Full Text PDF

Bottom-up proteomic approaches depend on the efficient digestion of proteins into peptides for mass spectrometric analysis. Sample preparation strategies, based on magnetic beads, filter-aided systems, or in-solution digests, are commonly used for proteomic analysis. Time-intensive methods like filter-aided sample preparation (FASP) have led to the development of new, more time-efficient filter-based strategies like suspension trappings (S-Traps) or magnetic bead-based strategies like SP3.

View Article and Find Full Text PDF

Water-stable perovskite-silica nanocomposites for encoded microbeads construction and multiplexed detection.

J Colloid Interface Sci

March 2024

Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China; CAS Key Lab of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, People's Republic of China. Electronic address:

All-inorganic lead halide perovskite nanocrystals exhibiting bright luminescence have great potential as fluorescence elements for optical encoding. However, their limited stability in water hinders the application in biosensing. In this study, novel optical encoded microbeads based on CsPbX (X = Cl, Br) nanocrystals are developed and applied in bead-based suspension arrays for the first time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!