A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bench-top testing of suction forces generated through endoscopic ultrasound-guided aspiration needles. | LitMetric

Background: Adequate needle size and tissue acquisition techniques for endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) need further elucidation. Moreover, the actual negative pressure and suction forces of FNA needles remain unknown. We evaluated the suction forces of 19-gauge, 22-gauge, and 25-gauge conventional FNA needles and side hole aspiration needles using conventional negative pressure and the slow pull technique.

Methods: Using a manometer, we determined the mean (SD) negative pressure and suction force for needle gauge, aspiration volume, and aspiration technique. We also evaluated the time to reach the maximum negative pressure.

Results: Suction force was comparatively higher in the 19-gauge needle when 50 ml of negative pressure was applied. Suction force using the slow pull method was very weak at 5% of pressure found with conventional methods. With the use of a 20-ml syringe, the time to reach the maximum negative pressure was 4 s in the 19-gauge needle, 11 s in the 22-gauge needle, and 80 s in the 25-gauge needle.

Conclusions: Bench-top testing showed that suction force increases with a larger gauge needle and larger aspiration volume. The slow pull method produces a very weak suction force. The time to reach the maximum negative pressure was longest in the 25-gauge needle.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jhbp.201DOI Listing

Publication Analysis

Top Keywords

negative pressure
24
suction force
20
suction forces
12
slow pull
12
time reach
12
reach maximum
12
maximum negative
12
bench-top testing
8
suction
8
testing suction
8