Background: In most countries, red blood cells (RBCs) can be stored up to 42 days before transfusion. However, observational studies have suggested that storage duration might be associated with increased morbidity and mortality. While clinical trials are under way, impaired metabolism has been documented in RBCs stored in several additive solutions (ASs). Here we hypothesize that, despite reported beneficial effects, storage in AS-3 results in metabolic impairment weeks before the end of the unit shelf life.

Study Design And Methods: Five leukofiltered AS-3 RBC units were sampled before, during, and after leukoreduction Day 0 and then assayed on a weekly basis from storage Day 1 through Day 42. RBC extracts and supernatants were assayed using a ultra-high-performance liquid chromatography separations coupled online with mass spectrometry detection metabolomics workflow.

Results: Blood bank storage significantly affects metabolic profiles of RBC extracts and supernatants by Day 14. In addition to energy and redox metabolism impairment, intra- and extracellular accumulation of amino acids was observed proportionally to storage duration, suggesting a role for glutamine and serine metabolism in aging RBCs.

Conclusion: Metabolomics of stored RBCs could drive the introduction of alternative ASs to address some of the storage-dependent metabolic lesions herein reported, thereby increasing the quality of transfused RBCs and minimizing potential links to patient morbidity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4469527PMC
http://dx.doi.org/10.1111/trf.12975DOI Listing

Publication Analysis

Top Keywords

red blood
8
rbc units
8
rbcs stored
8
storage duration
8
rbc extracts
8
extracts supernatants
8
rbc
5
storage
5
routine storage
4
storage red
4

Similar Publications

Design, Synthesis, and Imaging of a Stable Xanthene-Based Dye with NIR-II Emission up to 1450 nm.

Anal Chem

January 2025

Center for Advanced Materials Research & Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, P. R. China.

The development of long-wavelength near-infrared II (NIR-II, 900-1700 nm) dyes is highly desirable but challenging. To achieve both red-shifted absorption/emission and superior imaging capabilities, a donor-acceptor-donor (D-A-D) xanthene core was strategically modified by extending π-conjugated double bonds and enhancing electron-donating properties. Two dyes named and were synthesized and exhibited notably red-shifted absorption/emission peaks at 942/1250 and 1098/1450 nm, respectively.

View Article and Find Full Text PDF

Background: Incomplete adherence to daily tenofovir disoproxil fumarate/emtricitabine (TDF/FTC) reduces effectiveness. Adherence biomeasures (i.e.

View Article and Find Full Text PDF

Polyunsaturated fatty acids (PUFAs) including omega-3 and omega-6 are obtained from diet and can be measured objectively in plasma or red blood cells (RBCs) membrane biomarkers, representing different dietary exposure windows. In vivo conversion of omega-3 and omega-6 PUFAs from short- to long-chain counterparts occurs via a shared metabolic pathway involving fatty acid desaturases and elongase. This analysis leveraged genome-wide association study (GWAS) summary statistics for RBC and plasma PUFAs, along with expression quantitative trait loci (eQTL) to estimate tissue-specific genetically predicted gene expression effects for delta-5 desaturase (FADS1), delta-6 desaturase (FADS2), and elongase (ELOVL2) on changes in RBC and plasma biomarkers.

View Article and Find Full Text PDF

We investigated the and uses of pamoic acid functionalized gold nanoparticles (PA@AuNPs), with a focus on determining their safety and potential toxicity in living beings. To test this theory, the bacterial interaction of PA@AuNPs was studied using , , and cultures, as well as the inhibition of the bovine serum albumin (BSA) protein. The real-time polymerase chain reaction (RT-PCR) is used to measure the expression of target genes.

View Article and Find Full Text PDF

Objective: To investigate the role of endoscopic ultrasonography (EUS) in the diagnosis and treatment of upper gastrointestinal bleeding of unknown origin in liver cirrhosis, focusing on patients with recurrent treatment of esophageal and gastric varices who failed to identify the bleeding site under direct endoscopy.

Background: Esophagogastric variceal bleeding is one of the severe complications of decompensated liver cirrhosis, and serial endoscopic therapy can improve the long-term quality of life of patients. Most acute bleeding can be detected under direct endoscopy with thrombus or active bleeding, but there are still some patients with recurrent bleeding after repeated treatments, and it is difficult to find the bleeding site, especially in gastric variceal bleeding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!