Assessment of fatty liver grafts during orthotopic liver transplantation is a challenge due to the lack of real-time analysis options during surgery. Diffuse reflectance spectroscopy (DRS) could be a new diagnostic tool to quickly assess steatosis. Eight hundred and seventy-eight optical measurements were performed in vivo in 17 patients in liver tissue during surgery and ex vivo on liver resection specimens from 41 patients. Liver steatosis was quantified from the collected optical spectra and compared with the histology analysis from the measurement location by three independent pathologists. Twenty two patients were diagnosed with <5% steatosis, 15 patients had mild steatosis, and four had moderate steatosis. Severe steatosis was not identified. Intraclass correlation between the pathologists analysis was 0.949. A correlation of 0.854 was found between the histology and DRS analyses of liver steatosis ex vivo. For the same liver tissue, a correlation of 0.925 was demonstrated between in vivo and ex vivo DRS analysis for steatosis quantification. DRS can quantify steatosis in liver tissue both in vivo and ex vivo with good agreement compared to histopathology analysis. This analysis can be performed real time and may therefore be useful for fast objective assessment of liver steatosis in liver surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1111/tri.12517DOI Listing

Publication Analysis

Top Keywords

diffuse reflectance
8
reflectance spectroscopy
8
patients liver
8
liver
6
spectroscopy real-time
4
real-time quantification
4
quantification steatosis
4
steatosis liver
4
liver assessment
4
assessment fatty
4

Similar Publications

Composite coatings reinforced with varying mass fractions of SiC particles were successfully fabricated on 316 stainless steel substrates via laser cladding. The phase compositions, elemental distribution, microstructural characteristics, hardness, wear resistance and corrosion resistance of the composite coatings were analyzed using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Vickers hardness testing, friction-wear testing and electrochemical methods. The coatings have no obvious pores, cracks or other defects.

View Article and Find Full Text PDF

The human brain connectome is characterized by the duality of highly modular structure and efficient integration, supporting information processing. Newborns with congenital heart disease (CHD), prematurity, or spina bifida aperta (SBA) constitute a population at risk for altered brain development and developmental delay (DD). We hypothesize that, independent of etiology, alterations of connectomic organization reflect neural circuitry impairments in cognitive DD.

View Article and Find Full Text PDF

Photocatalytic reduction of CO to produce organic fuels is a promising strategy for addressing carbon reduction and energy scarcity. Transition metal carbides (TiCT ) are of particular interest due to their unique layered structures and excellent electrical conductivity. However, the practical application of TiCT is limited by the poor separation efficiency of photogenerated charge carriers and the low migration ability of photogenerated electrons.

View Article and Find Full Text PDF

Acoustic-phonetic perception refers to the ability to perceive and discriminate between speech sounds. Acquired impairment of acoustic-phonetic perception is known historically as "pure word deafness" and typically follows bilateral lesions of the cortical auditory system. The extent to which this deficit occurs after unilateral left hemisphere damage and the critical left hemisphere areas involved are not well defined.

View Article and Find Full Text PDF

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!