Automatic seizure detection technology is necessary and crucial for the long-term electroencephalography (EEG) monitoring of patients with epilepsy. This article presents a patient-specific method for the detection of epileptic seizures. The fractal dimensions of preprocessed multichannel EEG were firstly estimated using a k-nearest neighbor algorithm. Then, the feature vector constructed for each epoch was fed into a trained gradient boosting classifier. After a series of postprocessing, including smoothing, threshold processing, collar operation, and union of seizure detections in a short time interval, a binary decision was made to determine whether the epoch belonged to seizure status or not. Both the epoch-based and event-based assessments were used for the performance evaluation of this method on the EEG data of 21 patients from the Freiburg dataset. An average epoch-based sensitivity of 91.01% and a specificity of 95.77% were achieved. For the event-based assessment, this method obtained an average sensitivity of 94.05%, with a false detection rate of 0.27/h.