The aim of this study was to compare the outcomes of vestibular tests and the residual hearing of patients who have undergone full insertion cochlear implant surgery using the round window approach with a hearing preservation protocol (RW-HP) or the standard cochleostomy approach (SCA) without hearing preservation. A prospective study of 34 adults who underwent unilateral cochlear implantation was carried out. One group was operated using the RW-HP (n = 17) approach with Med-El +Flex(SOFT) electrode array with full insertion, while the control group underwent a more conventional SCA surgery (n = 17) with shorter perimodiolar electrodes. Assessments of residual hearing, cervical vestibular-evoked myogenic potentials (cVEMP), videonystagmography, subjective visual vertical/horizontal (SVH/SVV) were performed before and after surgery. There was a significantly (p < 0.05) greater number of subjects who exhibited complete or partial hearing preservation in the deep insertion RW-HP group (9/17) compared to the SCA group (2/15). A higher degree of vestibular loss but a lower degree of vertigo symptoms could be seen in the RW-HP group, but the differences were not statistically significant. It is possible to preserve residual hearing to a certain extent also with deep insertion. Full insertion with hearing preservation was less harmful to residual hearing particularly at 125 Hz (p < 0.05), than was the standard cochleostomy approach.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00405-014-3451-2DOI Listing

Publication Analysis

Top Keywords

residual hearing
16
hearing preservation
16
full insertion
12
round window
8
cochlear implant
8
implant surgery
8
hearing
8
standard cochleostomy
8
cochleostomy approach
8
deep insertion
8

Similar Publications

Background And Objectives: Jugular paragangliomas (JPG) pose a surgical challenge because of their vascularity and complex location. Stereotactic radiosurgery (SRS) offers a minimally invasive management for patients with JPG. Our aim was to evaluate outcomes of Gamma Knife radiosurgery (GKRS) for the treatment of JPG over the long term.

View Article and Find Full Text PDF

Background: Residual speech sound disorder (RSSD) is a high-prevalence condition that negatively impacts social and academic participation. Telepractice service delivery has the potential to expand access to technology-enhanced intervention methods that can help remediate RSSD, but it is not known whether remote service delivery is associated with a reduction in the efficacy of these methods. This project will systematically measure the outcomes of visual-acoustic biofeedback intervention when delivered in-person or online.

View Article and Find Full Text PDF

Wide dynamic range compression (WDRC) and noise reduction both play important roles in hearing aids. WDRC provides level-dependent amplification so that the level of sound produced by the hearing aid falls between the hearing threshold and the highest comfortable level of the listener, while noise reduction reduces ambient noise with the goal of improving intelligibility and listening comfort and reducing effort. In most current hearing aids, noise reduction and WDRC are implemented sequentially, but this may lead to distortion of the amplitude modulation patterns of both the speech and the noise.

View Article and Find Full Text PDF

Sudden Sensorineural Hearing Loss Following Electric Shock: A Case Report with Literature Review.

Iran J Otorhinolaryngol

January 2025

Senior Resident, Department of ENT and Head & Neck Surgery , All India Institute of Medical Sciences, Bathinda, Punjab, India.

Introduction: Electric shock occurs when electricity passes through the body, causing a range of symptoms from mild tingling to potentially life-threatening injuries such as burns, seizures, and cardiac arrest. In rare cases, Sudden Sensorineural Hearing Loss (SSNHL) has also been associated with an electric shock.

Case Report: A 35-year-old male presented with left-sided hearing loss following an electric shock.

View Article and Find Full Text PDF

EXPRESS: Vocal and musical emotion perception, voice cue discrimination, and quality of life in cochlear implant users with and without acoustic hearing.

Q J Exp Psychol (Hove)

January 2025

Department of Otorhinolaryngology / Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.

This study aims to provide a comprehensive picture of auditory emotion perception in cochlear implant (CI) users by (1) investigating emotion categorization in both vocal (pseud-ospeech) and musical domains, and (2) how individual differences in residual acoustic hearing, sensitivity to voice cues (voice pitch, vocal tract length), and quality of life (QoL) might be associated with vocal emotion perception, and, going a step further, also with musical emotion perception. In 28 adult CI users, with or without self-reported acoustic hearing, we showed that sensitivity (d') scores for emotion categorization varied largely across the participants, in line with previous research. However, within participants, the d' scores for vocal and musical emotion categorization were significantly correlated, indicating similar processing of auditory emotional cues across the pseudo-speech and music domains and robustness of the tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!