Objective: This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones.
Design: Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period.
Study Sample: Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability.
Results: The results suggested that (1) only small adjustments were needed to reach equivalent TDH-39P thresholds, (2) pure-tone thresholds obtained with HDA200 circumaural earphones had reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise-band thresholds improved with broader stimulus bandwidth and was either equal to or better than pure-tone thresholds, and (4) frequency-specificity declined with stimulus bandwidths greater than one equivalent rectangular band, which could complicate early detection of hearing changes that occur within a narrow frequency range.
Conclusions: These data suggest that circumaural earphones such as the HDA200 headphones provide better reliability for audiometric testing as compared to the TDH-39P earphones. These data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4559258 | PMC |
http://dx.doi.org/10.3109/14992027.2014.979300 | DOI Listing |