Application of pyrolysis-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry with electron-ionization or resonance-enhanced-multi-photon ionization for characterization of crude oils.

Anal Chim Acta

Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, Institute of Chemistry, University of Rostock, 18059 Rostock, Germany; Joint Mass Spectrometry Centre, Cooperation Group Comprehensive Molecular Analytics, Institute of Ecological Chemistry, Helmholtz Zentrum München-German Research Center of Environmental Health (GmbH), Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany.

Published: January 2015

A novel analytical system for gas-chromatographic investigation of complex samples has been developed, that combines the advantages of several analytical principles to enhance the analytical information. Decomposition of high molecular weight structures is achieved by pyrolysis and a high separation capacity due to the chromatographic step provides both an universal as well as a selective and sensitive substance detection. The latter is achieved by simultaneously applying electron ionization quadrupole mass spectrometry (EI-QMS) for structural elucidation and [1+1]-resonance-enhanced-multi-photon ionization (REMPI) combined with time-of-flight mass spectrometry (ToFMS). The system has been evaluated and tested with polycyclic aromatic hydrocarbon (PAH) standards. It was applied to crude oil samples for the first time. In such highly complex samples several thousands of compounds are present and the identification especially of low concentrated chemical species such as PAH or their polycyclic aromatic sulfur containing heterocyclic (PASH) derivatives is often difficult. Detection of unalkylated and alkylated PAH together with PASH is considerably enhanced by REMPI-ToFMS, at times revealing aromatic structures which are not observable by EI-QMS due to their low abundance. On the other hand, the databased structure proposals of the EI-QMS analysis are needed to confirm structural information and isomers distinction. The technique allows a complex structure analysis as well as selective assessment of aromatic substances in one measurement. Information about the content of sulfur containing compounds plays a significant role for the increase of efficiency in the processing of petroleum.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2014.11.030DOI Listing

Publication Analysis

Top Keywords

complex samples
8
well selective
8
mass spectrometry
8
polycyclic aromatic
8
application pyrolysis-mass
4
spectrometry
4
pyrolysis-mass spectrometry
4
spectrometry pyrolysis-gas
4
pyrolysis-gas chromatography-mass
4
chromatography-mass spectrometry
4

Similar Publications

Cardiovascular Outcomes in Patients with Complex Type 2 Diabetes Mellitus Treated with the Dual SGLT Inhibitor Sotagliflozin: A Meta-analysis.

Diabetes Ther

January 2025

The State Key Laboratory Management and Control for Complex Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.

Introduction: Scientific publications have shown sodium-glucose co-transporter-2 (SGLT2) inhibitors to have several beneficial effects in patients with complex type 2 diabetes mellitus (T2DM). However, sodium-glucose co-transporter-1 (SGLT-1) inhibitor is still under investigation in clinical trials. Recently, a dual inhibitor of sodium-glucose co-transporter (SGLT1/2), sotagliflozin, has been approved for use in patients with T2DM.

View Article and Find Full Text PDF

Background: Shoulder dystocia, a challenging condition for obstetricians, poses significant risks to both maternal and neonatal health, including maternal postpartum hemorrhage, neonatal hypoxia, and brachial plexus injury. Despite being unpredictable and unpreventable, effective management can mitigate these risks. Miscommunication and poor leadership are responsible for 72% of medical errors, which further highlights the importance of robust leadership skills in obstetric emergencies.

View Article and Find Full Text PDF

A simple cavity-enhanced laser-based heater for reflective samples.

Rev Sci Instrum

January 2025

Institute for Physical Chemistry, University of Göttingen, 37077 Göttingen, Germany.

Surface science instruments require excellent vacuum to ensure surface cleanliness; they also require control of sample temperature, both to clean the surface of contaminants and to control reaction rates at the surface, for example, for molecular beam epitaxy and studies of heterogeneous catalysis. Standard approaches to sample heating within high vacuum chambers involve passing current through filaments of refractory metals, which then heat the sample by convective, radiative, or electron bombardment induced heat transfer. Such hot filament methods lead to outgassing of molecules from neighboring materials that are inadvertently heated; they also produce electrons and ions that may interfere with other aspects of the surface science experiment.

View Article and Find Full Text PDF

Exogenous Coreactant-Free Electrocatalytic Reactive Oxygen Species-Driven Dual-Signal Molecularly Imprinted Electrochemiluminescence Sensor for the Detection of Trenbolone.

Anal Chem

January 2025

The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.

Conventional dual-signal electrochemiluminescence (ECL) sensors feature high sensitivity and reliability, but the involvement of coreactants inevitably results in a complex configuration and shows reproducibility risk. Here, we propose an exogenous coreactant-free dual-signal platform, comprising luminol (anodic luminophore), CdSe quantum dots (cathodic luminophore), and CoO/TiC electrocatalyst (coreaction promoter). At different redox potentials, CoO/TiC induces water oxidation and oxygen reduction to produce OH and O radicals, which subsequently drive cathodic and anodic ECL emission, respectively.

View Article and Find Full Text PDF

Background: Single-cell RNA sequencing (scRNA-seq) has improved our ability to characterize rare cell populations. In practice, cells from different tissues or donors are simultaneously loaded onto the instrument (multiplexed) at the recommended (standard loading) or higher (superloading) numbers to save time and money. Although cost-effective, superloading can stymie computational analyses owing to high multiplet rates and sample complexity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!