Background: Endovascular therapy for aortoiliac (AI) lesions using stents is widely accepted. However, the long-term outcome of 2 different types of nitinol stents for AI lesions is unknown. The aim of this study was to examine the long-term outcome of the SMART and Luminexx nitinol stents for the treatment of de novo AI lesions.

Methods: This study was a multicenter retrospective analysis of a prospectively maintained database. The study enrolled consecutive patients undergoing primary stenting for de novo AI artery stenosis between January 2005 and December 2009. A total of 1503 lesions in 1229 patients treated with SMART or Luminexx primary stenting were enrolled. The primary end point was primary patency, secondary end points were the primary assisted patency, secondary patency, and major adverse limb events (MALEs), which included major amputation and major reintervention. To minimize the differences between the groups, a propensity score matching analysis was performed, and 284 lesions per group were analyzed to identify outcomes.

Results: After the propensity score matching analysis, the lesion length was 60 ± 37 and 57 ± 31 mm (P = .275), and the reference vessel diameter was 8.2 ± 1.5 and 8.3 ± 1.5 mm (P = .482) in the SMART and Luminexx groups, respectively. The primary patency at 3 years was not significantly different between the groups (83.5% vs 82.2%, P = .842, respectively). The assisted primary patency and secondary patency rates were also not significantly different (91.7% vs 93.2%, P = .340, 99.2% vs 98.8%, P = .922). In addition, the MALE rate was not significantly different between the groups (98.3% vs 97.3%, P = .821).

Conclusion: The current data suggest that the use of nitinol stents for the AI artery provided good long-term patency and freedom from MALE for 3 years of follow-up, regardless of whether SMART or Luminexx stents were used.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0003319714564207DOI Listing

Publication Analysis

Top Keywords

smart luminexx
16
nitinol stents
12
primary patency
12
patency secondary
12
luminexx nitinol
8
long-term outcome
8
primary stenting
8
secondary patency
8
propensity score
8
score matching
8

Similar Publications

Objectives: To investigate the risk factors and biomechanical mechanisms of in-stent restenosis (ISR) in central venous occlusive disease (CVOD).

Patients And Methods: This retrospective study consecutively included 77 maintenance hemodialysis (MHD) patients with CVOD who received the first percutaneous transluminal angioplasty with stenting (PTS) due to symptomatic CVOD in a tertiary hospital. The mean age was 59.

View Article and Find Full Text PDF

Background And Purpose: Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents.

Material And Methods: We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions.

View Article and Find Full Text PDF

Background: Endovascular therapy for aortoiliac (AI) lesions using stents is widely accepted. However, the long-term outcome of 2 different types of nitinol stents for AI lesions is unknown. The aim of this study was to examine the long-term outcome of the SMART and Luminexx nitinol stents for the treatment of de novo AI lesions.

View Article and Find Full Text PDF

Aims: Iliac artery stenting is commonly performed via the ipsilateral or contralateral femoral artery. However, transradial intervention is less invasive than the transfemoral approach. We evaluated initial results of transradial iliac artery stenting.

View Article and Find Full Text PDF

Background: Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents.

Purpose: To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!