Aortic prosthesis-patient mismatch in patients with paradoxical low flow severe aortic stenosis: a dreadful combination.

Arch Cardiovasc Dis

CHU de Limoges, hôpital Dupuytren, pôle « Cœur-Poumon-Rein », service de cardiologie, 87042 Limoges, France. Electronic address:

Published: January 2015

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acvd.2014.10.004DOI Listing

Publication Analysis

Top Keywords

aortic prosthesis-patient
4
prosthesis-patient mismatch
4
mismatch patients
4
patients paradoxical
4
paradoxical low
4
low flow
4
flow severe
4
severe aortic
4
aortic stenosis
4
stenosis dreadful
4

Similar Publications

Background: Lifetime treatment of aortic valve disease is a matter of increasing debate. Although the risks of a second aortic valve intervention are recognized, little attention has been given to the challenges of a third.

Objectives: This study delves into the clinical characteristics, indications, and outcomes of patients undergoing 3 aortic valve interventions.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Transcatheter Aortic Valve-in-Valve Implantation with Newer Generation Evolut Valve by Size of Failed Bioprosthesis.

Anatol J Cardiol

January 2025

Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA ; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA.

Background: To evaluate the clinical outcomes of valve-in-valve transcatheter aortic valve replacement (ViV TAVR) with newer-generation self-expanding Evolut valves according to the size of the failed surgical bioprosthesis.

Methods: This single-center retrospective study evaluated consecutive patients undergoing ViV TAVR with the Evolut Pro/Pro+/Fx between 2018 and 2022. These patients were compared based on the true internal diameter (ID) of the failed bioprosthesis, specifically ≤19 mm (small group) vs.

View Article and Find Full Text PDF

Background: The short-term and midterm impact of gender differences on transcatheter aortic valve implantation (TAVI) has been studied. However, the impact on long-term clinical outcomes remains unclear. The objective of the study was to investigate the impact of gender differences after TAVI on long-term clinical outcomes and structural valve deterioration (SVD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!