A reliable, simple and rapid diagnostic method that can be helpful in pulmonary tuberculosis diagnosis is urgently needed. Loop-mediated Isothermal Amplification (LAMP) allows DNA to be amplified rapidly at a constant temperature. In this study, real-time fluorescence LAMP was evaluated to rapidly detect Mycobacterium tuberculosis in sputum and was compared to the performance of real-time fluorescence quantitative PCR (Q-PCR). All the standard MTB strains were successfully detected and limit of detection (LOD) was 10(2)CFU/mL by real-time fluorescence LAMP within 20min. In light of MTB in sputum, the real-time fluorescence LAMP method yielded a sensitivity of 98.0% and a specificity of 78.3%, compared to Q-PCR assay, which yielded a sensitivity of 96.0% and a specificity of 82.6% for PTB diagnosis. There was an excellent overall agreement between LAMP and Q-PCR for PTB (κ=0.315) and non-PTB (κ=0.862). Therefore, the real-time fluorescence LAMP assay is a rapid, sensitive, and specific method to detect pulmonary tuberculosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mimet.2014.12.013 | DOI Listing |
J Exp Clin Cancer Res
January 2025
Department of Hepato-Biliary-Pancreatic Surgery, General Surgery, Huadong Hospital, Fudan University, Shanghai, 200040, PR China.
Purpose: Glucose starvation induces the accumulation of disulfides and F-actin collapse in cells with high expression of SLC7A11, a phenomenon termed disulfidptosis. This study aimed to confirm the existence of disulfidptosis in pancreatic ductal adenocarcinoma (PDAC) and elucidate the role of Cancer Susceptibility 8 (CASC8) in this process.
Methods: The existence of disulfidptosis in PDAC was assessed using flow cytometry and F-actin staining.
Anal Chim Acta
February 2025
State Key Laboratory of Applied Organic Chemistry and Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, College of Chemistry and Chemical Engineering, Lanzhou University, Gansu, Lanzhou, 730000, China. Electronic address:
The presence of lead ion (Pb) in groundwater poses a serious risk to human health, even at low levels. Therefore, it is essential to develop a new strategy for both selective detection and effective removal of Pb in groundwater, which has been rarely reported. Here, we developed a multi-functional chitosan-based fluorescent sensing membrane (CM-L/CG) by using a casting method for the sensitive/selective detection and removal of Pb in groundwater.
View Article and Find Full Text PDFFish Shellfish Immunol
January 2025
Key Laboratory of Freshwater Aquatic Genetic Resources Ministry of Agriculture and Rural Affairs, Key Laboratory of Exploration and Utilization of Aquatic genetic Resources, Ministry of Education, International Research Center for Marine Biosciences, Ministry of Science and Technology, Shanghai Ocean University, Shanghai, China. Electronic address:
Frog virus 3-like ranaviruses (FV3-like viruses), particularly FV3 (Frog virus 3), represent typical species within the genus Ranavirus, primarily infecting amphibians and reptiles, thereby posing serious threats to aquaculture and biodiversity conservation. We designed a pair of universal primers and a probe targeting the conserved region of the major capsid protein (MCP) genes of FV3-like viruses. By integrating recombinase-aided amplification (RAA) with lateral flow dipstick (LFD) technology and real-time fluorescence (RF) modification, we established RAA-LFD and RF-RAA assays.
View Article and Find Full Text PDFEcotoxicol Environ Saf
January 2025
Department of Pediatrics, The Third Xiangya Hospital of Central South University, Changsha 410013, China. Electronic address:
Glyphosate, a widely used herbicide globally, has prompted concerns regarding its potential health impacts. This study aimed to explore the link between glyphosate exposure and renal function by combining NHANES, a zebrafish model, and metabolomics. A cross-sectional analysis of 2013-2014 NHANES data investigated the relationship between glyphosate exposure and renal function [albumin-to-creatinine ratio (ACR) and estimated glomerular filtration rate (eGFR)].
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Key Laboratory of Laboratory Medical Diagnostics, Ministry of Education, Department of Laboratory Medicine, Chongqing Medical University, Chongqing, China. Electronic address:
Isothermal amplification-based nucleic acid detection technologies have become rapid and efficient tools for molecular diagnostics. Sequence-specific monitoring methods are crucial for isothermal amplification, as they help identify the occurrence of extended primer dimers, which can lead to false positive results. Fluorescent aptamers are promising tools for real-time monitoring of isothermal amplification but are inherently limited by thermostability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!