In view of the importance of zero-dose background (null signal) in influencing the coefficient of variation in low-dose region, a technique for the estimation of the same from composite (gross) signal is developed for CaSO4:Dy-based personnel monitoring system being used in India. The technique is based on simple analysis of glow curves (GCs) of unexposed and exposed dosemeters, evolution of trend/model for the zero-dose curves, generation of simulation protocol for individual zero-dose curves, establishment of characteristics of GCs of exposed dosemeters and finally preparation of an algorithm to segregate the components from composite signal. The technique offers the separation of real-time background and gives superior results over other method of approximation of the background. The results also prove efficiency of the empirical trending and simulation protocol of background GCs. The proposed technique can be implemented in routine monitoring without any extra man hours and reader time.