Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267165 | PMC |
http://dx.doi.org/10.1155/2014/461534 | DOI Listing |
Lasers Med Sci
January 2025
Shanxi Medical University School and Hospital of Stomatology, Shanxi Bethune Hospital, Taiyuan, Shanxi, China.
Green lasers have a stronger effect on promoting osteoblast differentiation, which is critical for orthodontic tooth retention. This study investigated the impact of green laser photobiomodulation on orthodontic tooth retention in rats. A total of 100 male Sprague-Dawley rats were divided into two groups: Group A (control) and Group B (green laser irradiation).
View Article and Find Full Text PDFNatl J Maxillofac Surg
November 2024
Fellow of International Association of Oral and Maxillofacial Surgeons, Chicago, USA.
Purpose: This study was conducted to check the efficacy of PUNPLAPOT-innovative Template for positioning of the bone miniplate for fracture fixation.
Material And Methods: Twenty dried mandible specimens were used in this study. The specimens were then divided into two groups using random sampling.
BMC Oral Health
January 2025
Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230, Sıhhiye/Altındağ, Ankara, Turkey.
Background: The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.
Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).
Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.
BMC Oral Health
January 2025
Department of Endodontics, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Objectives: This study aimed to compare the marginal adaptation of a cold ceramic (CC) sealer with the single-cone obturation technique with that of an AH-26 sealer with the lateral compaction technique in single-canal teeth.
Materials And Methods: In this in vitro experimental study, the root canals of 24 extracted single-rooted single-canal teeth were instrumented to F3 files by the crown-down technique and randomly assigned to 2 groups (n = 12). The root canals were obturated with a CC sealer and single-cone obturation technique with 4% gutta-percha in group 1 and with an AH-26 sealer and lateral compaction technique with 2% gutta-percha in group 2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!