A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiofrequency configuration to facilitate bilateral breast (31) P MR spectroscopic imaging and high-resolution MRI at 7 Tesla. | LitMetric

Purpose: High-resolution MRI combined with phospholipid detection may improve breast cancer grading. Currently, configurations are optimized for either high-resolution imaging or (31) P spectroscopy. To be able to perform both imaging as well as spectroscopy in a single session, we integrated a (1) H receiver array into a (1) H-(31) P transceiver at 7T. To ensure negligible signal loss due to coupling between elements, we investigated the use of a floating decoupling loop to enable bilateral MRI and (31) P MRS.

Methods: Two quadrature double-tuned radiofrequency coils were designed for bilateral breast MR with active detuning at the (1) H frequency. The two coils were placed adjacent to each other and decoupled for both frequencies with a single resonant floating loop. Sensitivity of the bilateral configuration, facilitating space for a 26-element (1) H receive array, was compared with a transceiver configuration.

Results: The floating loop was able to decouple the elements over 20 dB for both frequencies. Enlargement of the elements, to provide space for the receivers, and the addition of detuning electronics altered the (31) P sensitivity by 0.4 dB.

Conclusion: Dynamic contrast-enhanced scans of 0.7 mm isotropic, diffusion-weighted imaging, and (31) P MR spectroscopic imaging can be acquired at 7T in a single session as demonstrated in a patient with invasive ductal carcinoma.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25573DOI Listing

Publication Analysis

Top Keywords

bilateral breast
8
spectroscopic imaging
8
high-resolution mri
8
single session
8
floating loop
8
imaging
5
radiofrequency configuration
4
configuration facilitate
4
bilateral
4
facilitate bilateral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!