Background: Mobile-bearing total knee prostheses were designed to reduce wear and improve implant survivorship following total knee arthroplasty. However, the benefit of mobile-bearing total knee arthroplasty remains unproven. Both mobile-bearing and fixed-bearing total knee arthroplasty implants are available in posterior-stabilized and non-posterior-stabilized designs. With the latter, the implant does not recreate the function of the posterior cruciate ligament (PCL) with a posterior-stabilizing cam mechanism. The purpose of the present study was to compare mobile-bearing, non-posterior-stabilized devices with fixed-bearing, non-posterior-stabilized devices used in total knee arthroplasty through a novel multinational study design.

Methods: Through the use of a distributed health data network, primary total knee arthroplasties performed for osteoarthritis from 2001 to 2010 were identified from six national and regional total joint arthroplasty registries. Multivariate meta-analysis was performed with use of linear mixed models, with the primary outcome of interest being revision for any reason. Survival probabilities and their standard errors were extracted from each registry for each unique combination of the covariates.

Results: A total of 319,616 patients (60% female) underwent non-posterior-stabilized total knee arthroplasty. A fixed-bearing, non-posterior-stabilized design was used in 258,190 (81%) of the knees and a mobile-bearing, non-posterior-stabilized design in 61,426 (19%) of the knees. Sixty-nine percent of the patients who received a fixed-bearing implant were over sixty-five years of age, compared with 63% of those who received a mobile-bearing implant. Mobile-bearing designs had a higher risk of revision, with a hazard ratio of 1.43 (95% confidence interval, 1.36 to 1.51; p < 0.001).

Conclusions: Previous comparisons of mobile-bearing and fixed-bearing total knee arthroplasty outcomes have been inconclusive. The current study utilized an advanced, harmonized distributed analysis of six national and regional joint-replacement registries. To our knowledge, it is the largest analysis of mobile-bearing total knee arthroplasty to date. Mobile-bearing, non-posterior-stabilized designs presented a greater risk of failure than was found for fixed-bearing, non-posterior-stabilized designs. Caution should be used in the selection of the mobile-bearing non-posterior-stabilized design for total knee replacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4271422PMC
http://dx.doi.org/10.2106/JBJS.N.00466DOI Listing

Publication Analysis

Top Keywords

total knee
40
knee arthroplasty
28
mobile-bearing non-posterior-stabilized
16
total
12
mobile-bearing total
12
non-posterior-stabilized designs
12
fixed-bearing non-posterior-stabilized
12
non-posterior-stabilized design
12
knee
11
mobile-bearing
11

Similar Publications

Purpose: Knee pain is a characteristic symptom of early-stage knee osteoarthritis. Recently, the association between knee symptoms and infrapatellar fat pad (IFP) degeneration has garnered attention. This study aimed to clarify the association between ultrasound-derived size and echo intensity (EI) in the IFP and knee symptoms.

View Article and Find Full Text PDF

Background: Complete blood cell count-based ratios (CBRs), including the neutrophil-lymphocyte ratio (NLR) and monocyte-lymphocyte ratio (MLR), are inflammatory markers associated with postoperative morbidity. Given the link between the surgical stress response and complications after total joint arthroplasty (TJA), this study aimed to evaluate whether higher preoperative CBR values predict greater postoperative benefits associated with dexamethasone utilization.

Methods: The Premier Healthcare Database was queried for adult patients who underwent primary, elective total hip or knee arthroplasty (THA or TKA).

View Article and Find Full Text PDF

Background: Early knee effusion is a common phenomenon after total knee arthroplasty (TKA), with potential clinical implications. Unlike traditional alloy knee prostheses, the polyetheretherketone (PEEK) knee system has radiographic transparency on magnetic resonance (MR) scans, which allows analysis of prosthetic knee effusion. We aimed to identify the distribution and volume of knee effusion after TKA with the PEEK prosthesis with use of MR imaging and to analyze whether dynamic changes in effusion were correlated with serum inflammatory marker changes and knee function recovery.

View Article and Find Full Text PDF

Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA).

Methods: MSSA and E.

View Article and Find Full Text PDF

Background: Two-stage revision in infected total knee arthroplasty increases the risk of blood loss and the need for transfusion. The present study aimed to test the hemostatic efficacy of a bipolar sealer to reduce blood loss and transfusion requirements after the first stage in patients affected by peri-prosthetic knee infections.

Methods: Twenty-four patients undergoing 2-stage arthroplasty for infected TKA using a bipolar sealer (Haemodiss, Kylix, Naples, IT) were compared with 24 patients of a historical control group in which conventional electrocautery was used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!