Objective: Transarticular facet screws restore biomechanical stability to the cervical spine when posterior cervical anatomy has been compromised. This study compares the more recent, less invasive, and briefer transarticular facet screw system without rods with the lateral mass screw system with rods.

Methods: For this study, 6 human cervical spines were obtained from cadavers. Transarticular facet screws without rods were inserted bilaterally into the inferior articular facets at the C5-C6 and C5-C6-C7 levels. Lateral mass screws with rods were inserted bilaterally at the same levels using Magerl's technique. All specimens underwent range of motion (ROM) testing by a material testing machine for flexion, extension, lateral bending, and axial rotation.

Results: Both fixation methods, transarticular facet screws without rods and lateral mass screws with rods, reduced all ROM measurements and increased spinal stiffness. No statistically significant differences between the 2 stabilization methods were found in ROM measurements for 1-level insertions. However, in 2-level insertions, ROM for the nonrod transarticular facet screw group was significantly increased for flexion-extension and lateral bending.

Conclusions: Transarticular facet screws without rods and lateral mass screws with rods had similar biomechanical stability in single-level insertions. For 2-level insertions, transarticular facet screws without rods are a valid option in cervical spine repair.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2014.12.008DOI Listing

Publication Analysis

Top Keywords

screws rods
36
transarticular facet
32
facet screws
24
lateral mass
20
mass screws
16
rods lateral
12
screws
10
rods
10
transarticular
8
facet
8

Similar Publications

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).

View Article and Find Full Text PDF

Rationale: Alkaptonuria (AKU) is a rare, inherited metabolic disease caused by deficient activity of homogentisic acid oxidase, leading to the accumulation of homogentisic acid and its oxidized product, benzoquinone acetic acid. These compounds cause black discoloration of cartilage, degeneration, inflammation, and calcification of intervertebral disks and large joints, resulting in pain and impaired quality of life. Despite its debilitating effects, there are no curative treatments for AKU, and management remains supportive.

View Article and Find Full Text PDF

A Novel Dynamic Growth Rod Inducing Spinal Growth Modulation for the Correction of Spinal Deformities.

JOR Spine

March 2025

Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.

Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.

View Article and Find Full Text PDF

Introduction: Congenital lumbar kyphosis is present in about 15% of patients with myelomeningocele. Worsening of deformity with complications such as chronic skin ulcers and bone exposure is common. In patients under 8 years of age, treatment becomes even more challenging: in addition to resecting the apex of the kyphotic deformity, we should ideally stabilize the spine with fixation methods that do not interrupt the growth of the rib cage, associated with the challenging pelvic fixation in this population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!