A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulsatile venoarterial perfusion using a novel synchronized cardiac assist device augments coronary artery blood flow during ventricular fibrillation. | LitMetric

Patients with cardiogenic shock have a very high mortality. Here we report the first use of a percutaneous pulsatile cardiac assist device, based on a diagonal pump synchronized with the heart cycle by means of an electrocardiographic signal in adult pigs. Eight domestic pigs underwent mandatory ventilation. During sinus rhythm, there were no differences between pulsatile and nonpulsatile perfusion with regard to pulmonary artery pressure, pulmonary wedge pressure, central venous pressure, mean arterial pressure (MAP), mean pulse pressure, and mean coronary artery flow (CAF). After 2 min of complete cardiac arrest (ventricular fibrillation), circulatory support with the i-cor in venoarterial nonpulsatile extracorporeal membrane oxygenation (ECMO) mode (3 L/min) restored systemic circulation, with an increase of MAP to 78.3 mm Hg and CAF to 5.27 mL/min. After changing from ECMO settings to pulsatile mode (3 L/min, 75 bpm, pulse amplitude range 3500 rpm), MAP did not change significantly (75.6 mm Hg); however, CAF increased to 8.45 mL/min. After changing back to nonpulsatile mode, MAP remained stable (83.6 mm Hg), but CAF decreased to 4.85 mL/min. Thereafter, pulsatile cardiac assist was established with a reduced blood flow of 2.5 L/min, and the pulse amplitude range was extended to 4500 rpm. Under these conditions, MAP remained stable (71.0 mm Hg), but CAF significantly increased to 15.2 mL/min (P < 0.05). Percutaneous cardiac support using a venoarterial cardiac assist device equipped with a novel diagonal pump is able to restore and increase systemic and coronary circulation during ventricular fibrillation. Electrocardiographically triggered synchronized cardiac assist provides an additional increase of coronary artery flow. These promising results are to be confirmed in humans.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.12413DOI Listing

Publication Analysis

Top Keywords

cardiac assist
12
assist device
8
coronary artery
8
blood flow
8
ventricular fibrillation
8
pulsatile cardiac
8
mode 3 l/min
8
pulse amplitude
8
amplitude range
8
caf increased
8