Scanning electron microscopic evaluation of root canal surfaces prepared with three rotary endodontic systems: Lightspeed, ProTaper and EndoWave.

Niger J Clin Pract

Department of Conservative Dentistry and Endodontics, Bhopal, Madhya Pradesh, India.

Published: May 2015

Background And Objectives: The purpose of this in vitro study was to evaluate and compare the cleaning efficiency, preparation time, instrument deformation and fracture with LightSpeed (LS), ProTaper (PT) and EndoWave (Ew) rotary instruments.

Materials And Methods: A total of 45 freshly extracted human mandibular premolars were subjected for the study. They were divided into three groups, each group consisting of 15 teeth. Group 1: The canals were prepared with LS system; Group 2: PT rotary system, Group 3: Ew rotary system. All the groups were prepared according to manufacturer's recommendation, using 5.25% sodium hypochlorite and 17% ethylenediaminetetraacetic acid (dent wash, prime dent) alternately as an irrigants. Crowns of each tooth were removed with diamond disks at the level of cemento enamel junction. Canal length was determined by placing a size 10 K-file. The working length was 0.5 mm short of canal length. Two longitudinal grooves were prepared on the lingual and buccal surfaces of each root to facilitate vertical splitting with a chisel after canal instrumentation. The sections were then observed under scanning electron microscope for presence or absence of debris and smear layer and the photographs were taken at coronal, middle and apical 1/3 with a magnification of × 200 and × 1000 respectively. The time taken to enlarge each canal was recorded in minutes and seconds. The instruments were examined after every use for deformation. The scores recorded were statistically analyzed using one-way analysis of variance and Mann-Whitney test.

Results: There was statistically significant difference with regard to removal of debris and smear layer at coronal, middle and apical third for LS versus PT and LS versus Ew (P < 0.01). There was no significant difference between PT and Ew. The mean preparation time for LS, PT and Ew was 1.76, 2.50 and 2.75 respectively.

Interpretation And Conclusion: The study demonstrated that, LS instrumentation removed debris and smear layer effectively with shorter preparation time and Ew instrument showed deformation.

Download full-text PDF

Source
http://dx.doi.org/10.4103/1119-3077.147001DOI Listing

Publication Analysis

Top Keywords

preparation time
12
debris smear
12
smear layer
12
scanning electron
8
lightspeed protaper
8
protaper endowave
8
time instrument
8
instrument deformation
8
system group
8
group rotary
8

Similar Publications

Purpose Of Review: Addressing diabetes distress (DD), the emotional demands of living with diabetes, is a crucial component of diabetes care. Most individuals with type 2 diabetes and approximately half of adults with type 1 diabetes receive their care in the primary care setting. This review will provide guidance on addressing DD and implementing targeted techniques that can be tailored to primary care patients.

View Article and Find Full Text PDF

Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.

Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.

View Article and Find Full Text PDF

Purpose: Angioplasty of lower extremity arteries with calcification may result in flow-limiting dissection requiring bail-out stenting with unfavorable long-term outcomes. Vessel preparation prior to angioplasty may improve immediate results of the angioplasty and long-term patency. This prospective study assessed the 12-month outcomes of patients who underwent novel vessel preparation catheter, the FLEX Vessel Prep™ System (FLEX VP), prior to drug-coated balloon angioplasty (DCB-PTA).

View Article and Find Full Text PDF

Objective: This study aims to elucidate the impact of varying tourniquet application timings on postoperative pain and the bone cement interface following TKA.

Method: Patients who underwent TKA in our department between March 2021 and July 2023 were included in this study. They were randomly assigned to three groups: Group 1 used tourniquets throughout the operation, Group 2 applied tourniquets before the osteotomy, and Group 3 applied tourniquets after completing the osteotomy.

View Article and Find Full Text PDF

Background: Currently, there is no agreed-upon data collection tool for comprehensively structured documentation of Iranian traditional medicine (ITM) from the information management perspective. As ITM practice varies significantly from current medicine in diagnosis and treatment approaches, it is not appropriate to use data platforms or information systems developed for current medicine. Consequently, the collected data are non-comparable, reducing the verdicts' generalization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?