Purpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers.

Materials And Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments. All the patients completed the Turkish version of the Oral Health Impact Profile-14 (OHIP-14) and the visual analog scale (VAS) satisfaction questionnaires. Momentary retention forces of the overdentures were measured using a custom-made dynamic testing machine.

Results: Fifty-five patients were included in this study. No statistically significant association was detected between momentary retention forces and VAS scores (P > .05), but higher retention forces presented significantly better quality of life scores in the social disability and handicap domains of OHIP-14 (P < .05).

Conclusion: Within the limitations of this clinical study, it may be presumed that although higher instant retention force of an implant-retained overdenture provides better quality of life, it does not affect patient satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.3774DOI Listing

Publication Analysis

Top Keywords

retention forces
20
momentary retention
16
quality life
16
patient satisfaction
12
influence momentary
8
forces patient
8
satisfaction quality
8
life two-implant-retained
8
two-implant-retained mandibular
8
mandibular overdenture
8

Similar Publications

Purpose: This study aims to evaluate the effects of taper angle and the number of insertion-removal cycles on the retention force of 4 mol% yttria partially stabilized zirconia (4Y-PSZ) double crowns over time.

Materials And Methods: Primary and secondary crowns were fabricated using 4Y-PSZ with taper angles of 2°, 4°, and 6° (n=15). Retention force during crown removal was measured after applying 50-N and 100-N loads.

View Article and Find Full Text PDF

Wooden Plate Denture Reproduced Using Materials and Methods From 400 Years Ago.

Cureus

December 2024

Department of Oral and Maxillofacial Surgery, National Hospital Organization, Kyoto Medical Center, Kyoto, JPN.

This study aimed to reproduce a complete wooden plate denture, which was the first in the world to retain suction under negative pressure, using the same materials and methods from 400 years ago (i.e., the Edo period) to verify its masticatory performance.

View Article and Find Full Text PDF

Background: Isotopologues resulting from the labelling of molecules with deuterium have attracted interest due to the isotope effect observed in chemistry and biosciences. Isotope effect may also play out in noncovalent interactions and mechanisms leading to intermolecular recognition. In chromatography, differences in retention time between isotopologues, as well as between isotopomers have been observed resulting in two different elution sequences (isotope effects): the normal isotope effect when heavier isotopologues retain longer than lighter analogues, and the inverse isotope effect featuring the opposite elution order.

View Article and Find Full Text PDF

Aging disrupts multiple homeostatic processes, including autophagy, a cellular process for the recycling and degradation of defective cytoplasmic structures. Acute treatment with the autophagy inhibitor chloroquine blunts the maximal forces generated by the diaphragm muscle, but the mechanisms underlying neuromuscular dysfunction in old age remain poorly understood. We hypothesized that chloroquine treatment increases the presynaptic retention of the styryl dye FM 4-64 following high-frequency nerve stimulation, consistent with the accumulation of unprocessed bulk endosomes.

View Article and Find Full Text PDF

The separation and structural identification of glycans are of great bioanalytical importance. To obtain a good understanding of the structural flexibility of glycans, replica exchange molecular dynamics (REMD) simulations were used based on AMBER force field calculations to create ensembles of glycan structures. Nonpolar surface area (NPSA) calculations based on continuum solvation (CS) models (Dhakal, R.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!