A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Thoracic Spinal Cord Stimulation for Heart Failure as a Restorative Treatment (SCS HEART study): first-in-man experience. | LitMetric

AI Article Synopsis

  • Preclinical studies indicate that thoracic spinal cord stimulation (SCS) may enhance left ventricular function in patients with heart failure.
  • This study was conducted to assess the safety and effectiveness of SCS as a treatment for systolic heart failure in patients with specific conditions.
  • The trial involved 22 patients, revealing that SCS treatment led to significant improvements in heart function, symptoms, and overall quality of life, while no benefits were seen in patients who did not receive the treatment.

Article Abstract

Background: Preclinical studies suggest that neuromodulation with thoracic spinal cord stimulation (SCS) improves left ventricular (LV) function and remodeling in systolic heart failure (HF).

Objective: The purpose of this study was to evaluate the safety and efficacy of a SCS system for the treatment of systolic HF.

Methods: We performed a prospective, multicenter pilot trial in patients with New York Heart Association (NYHA) class III HF, left ventricular ejection fraction (LVEF) 20%-35%, and implanted defibrillator device who were prescribed stable optimal medical therapy. Dual thoracic SCS leads were used at the T1-T3 level. The device was programmed to provide SCS for 24 hours per day (50 Hz at pulse width 200 μs).

Results: We enrolled 22 patients from 5 centers:17 patients underwent implantation of a SCS device and 4 patients who did not fulfill the study criteria served as nontreated controls. No deaths or device-device interactions were noted during the 6-month period in the 17 SCS-treated patients. Fifteen of 17 completed the efficacy endpoint assessments: composite score improved by 4.2 ± 1.3, and 11 patients (73%) showed improvement in ≥4 of 6 efficacy parameters. There was significant improvement in NYHA class (3.0 vs 2.1, P = .002; 13/17 improved); Minnesota Living with Heart Failure Questionnaire (42 ± 26 vs 27 ± 22, P = .026; 12/17 improved); peak maximum oxygen consumption (14.6 ± 3.3 vs 16.5 ± 3.9 mL/kg/min, P = .013; 10/15 improved); LVEF (25% ± 6% vs 37% ± 8%, P<.001; 14/16 improved); and LV end-systolic volume (174 ± 57 vs 137 ± 37 mL, P = .002; 11/16 improved) but not in N-terminal prohormone brain natriuretic peptide. No such improvements were observed in the 4 nontreated patients.

Conclusion: The results of this first-in-human trial suggest that high thoracic SCS is safe and feasible and potentially can improve symptoms, functional status, and LV function and remodeling in patients with severe, symptomatic systolic HF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2014.12.014DOI Listing

Publication Analysis

Top Keywords

heart failure
12
thoracic spinal
8
spinal cord
8
cord stimulation
8
left ventricular
8
nyha class
8
scs
6
patients
6
heart
5
stimulation heart
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!