Purpose: Thoracic ultrasound (TUS) has been successfully used in the diagnosis of community-acquired pneumonia. Little is known about its diagnostic potential in ventilator-associated pneumonia (VAP). The purpose of this study was to systematically describe the morphology and temporal changes of sonographic patterns in mechanically ventilated patients and to evaluate the diagnostic performance characteristics of TUS-based VAP diagnoses.
Materials And Methods: Patients who were placed on invasive ventilation for reasons other than pneumonia and who were considered at risk for the development of VAP received daily TUS examinations while being closely monitored for the development of pneumonia.
Results: Fifty-seven patients were studied. The incidence of VAP was 21.1%. Sonographic patterns of reduced or absent lung aeration were found in 64.2% of examinations. The sonographic pattern of lung consolidation with either dynamic or static air bronchograms was 100% sensitive and 60% specific for VAP in those patients who developed clinical signs and symptoms compatible with pneumonia. The pretest and posttest probabilities were 0.38 and 0.6, respectively.
Conclusions: Sonographic patterns of abnormal aeration are frequently observed in mechanically ventilated patients. If sonographic lung consolidation with either static or dynamic air bronchograms is absent, VAP is highly unlikely. The presence of these sonographic patterns in patients with signs and symptoms suggestive of pneumonia significantly increases the probability of VAP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcrc.2014.11.021 | DOI Listing |
BMC Rheumatol
January 2025
Rheumatology Department, Al-Azhar University Faculty of Medicine for Girls, 74 Ali Amin St, Nasr City, PO 11727, Cairo, Egypt.
Background: Fibromyalgia Syndrome (FMS) is a chronic disabling musculoskeletal condition of unknown aetiology characterized by generalized musculoskeletal pain, extreme fatigue, mood disturbance, impaired cognition, and lack of refreshing sleep. Middle East pain syndrome (MEPS) is a newly described pollution-induced syndrome of hyperparathyroidism and fibromyalgia mimicking rheumatoid arthritis, characterized by the radiological presence of spur-like excrescences in terminal phalanges. This study aimed to explore the inflammatory nature of Middle East pain and Fibromyalgia syndromes.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Department of Orthopedics, Kaohsiung Medical University Hospital, Kaohsiung 807378, Taiwan.
The hospital-at-home (HaH) model delivers hospital-level acute care, including diagnostics, monitoring, and treatments, in a patient's home. It is particularly effective for managing conditions such as pneumonia. Point-of-care ultrasonography (PoCUS) is a key diagnostic tool in the HaH model, and it often serves as a substitute for imaging-based diagnosis in the HaH setting.
View Article and Find Full Text PDFJ Pediatr Urol
December 2024
Department of Urology, University of Iowa, Iowa City, IA, 52242, USA. Electronic address:
Introduction: Prior analysis of children with grade 3 and 4 congenital hydronephrosis demonstrated that renal medullary pyramidal thickness (PT) is predictive of subsequent pyeloplasty (area under the curve [AUC] = 0.78). The objective of this study was to further analyze the utility of sonographic measurements including PT, anteroposterior pelvic diameter (APD), and renal length with an expansion of the number of infants with hydronephrotic kidneys including grades 2, 3, and 4 hydronephrosis.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Department of Ultrasound, Peking University International Hospital, Beijing, China.
Sci Rep
December 2024
Department of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China.
Breast ultrasound is recommended for early breast cancer detection in China, but the rapid increase in imaging data burdens sonographers. This study evaluated the agreement between artificial intelligence (AI) software and sonographers in analyzing breast nodule features. Breast ultrasound images from two hospitals in Shanghai were analyzed by both the software and the sonographers for features including echotexture, echo pattern, orientation, shape, margin, calcification, and posterior echo attenuation.