Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In recent years, it has been reported that the urinary level of Liver-type fatty acid-binding protein (L-FABP) serves as a useful biomarker for diagnosing acute kidney injury (AKI) or sepsis complicated by AKI. However, because the urinary level of L-FABP is currently measured by enzyme-linked immunosorbent assay (ELISA), several days may elapse before the results of the measurement become available. We have newly developed a simplified kit, the Dip-test, for measuring the urinary level of L-FABP. The Dip-test was measured at 80 measurement points (22 points in noninfectious disease, 13 points in SIRS, 20 points in infectious disease, and 25 points in sepsis) in 20 patients. The urinary L-FABP levels as determined by ELISA in relation to the results of the Dip-test were as follows: 10.10 ± 12.85 ng/ml in patients with a negative Dip-test ([-] group), 41.93 ± 50.51 ng/ml in patients with a ± test ([±] group), 70.36 ± 73.70 ng/ml in patients with a positive test ([+] group), 1048.96 ± 2117.68 ng/ml in patients with a 2 + test ([2+] group), and 23,571.55 ± 21,737.45 ng/ml in patients with a 3 + test ([3+] group). The following tendency was noted: the stronger the positive Dip-test reaction, the higher the urinary L-FABP level. Multigroup comparison revealed a significant differences in the urinary L-FABP levels between the Dip-test (-) group and each of the other groups. In this study, the usefulness of the Dip-test, our newly developed simplified kit for measuring the urinary L-FABP level, is suggested.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jiac.2014.10.017 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!