Proteomic analysis of rat plasma with experimental autoimmune uveitis based on label-free liquid chromatography-tandem mass spectrometry (LC-MS/MS).

J Chromatogr B Analyt Technol Biomed Life Sci

Shandong Provincial Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases, China; Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Therapy of Ocular Diseases in Universities of Shandong, China; Eye Institute of Shandong University of Traditional Chinese Medicine, No. 48#, Yingxiongshan Road, Jinan 250002, China. Electronic address:

Published: January 2015

Uveitis is a severe autoimmune eye disease that can cause intraocular inflammation even lead to severe vision loss, and the occurrence of uveitis can be closely associated with abnormal expression of proteins. However, the abnormally expressed proteins involved in uveitis are not well identified. Using liquid chromatography-tandem mass spectrometry technique, we examined the alterations in proteomic expression profiling in rat plasma specimens related to experimental autoimmune uveitis (EAU) versus normal samples. In addition, the experimental verification was further performed using enzyme-linked immunosorbent assay (ELISA) for abnormally expressed proteins in EAU rat plasma. The results indicate that 62 proteins were upregulated and 106 proteins were downregulated in plasma from EAU rats compared with those in saline-treated samples. In the meantime, we observed that the plasma level of complement component 3 in EAU rats was upregulated versus saline-treated rats (from 92.32μg/mL to 168.92μg/mL), whereas the level of interleukin-1 receptor accessory protein was downregulated (from 1120.97pg/mL to 798.39pg/mL), and these results were highly in agreement with those of mass spectrometry determination. Taken together, our results indicate that liquid chromatography-tandem mass spectrometry analysis possesses a good resolution for peptides in plasma, and the findings will provide the baseline plasma dataset for EAU rats and the relevant information can contribute to future studies on the understanding the mechanism of uveitis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2014.11.015DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
16
rat plasma
12
liquid chromatography-tandem
12
chromatography-tandem mass
12
eau rats
12
experimental autoimmune
8
autoimmune uveitis
8
abnormally expressed
8
expressed proteins
8
plasma
7

Similar Publications

Double bond (C═C) position isomerism in unsaturated lipids can indicate abnormal lipid metabolism and pathological conditions. Novel chemical derivatization and mass spectrometry-based techniques are under continuing development to provide more accurate elucidation of lipid structure in finer structural detail. Here, we introduce a new ion chemistry for annotating lipid C═C positions, which is highly efficient for liquid chromatography-mass spectrometry-based lipidomics.

View Article and Find Full Text PDF

The occurrence of off-flavor in osmanthus absolutes has emerged as a significant concern that could hinder its broad market acceptance and associated economic development. In this study, key off-flavor molecules in industrial osmanthus absolute were identified through sensomics and chemometric approaches. A group of 10 off-flavor (OF) samples, eliciting smoky/phenolic, sweaty/sour, and spicy odors, were compared with 10 pleasant aroma (PA) samples through various analyses, including overall aroma assessment, comprehensive chemical profiling, aroma extract dilution analysis (AEDA), and orthogonal partial least-squares-discriminant analysis (OPLS-DA).

View Article and Find Full Text PDF

Wildfires at the wildland-urban interface (WUI) have been increasing in frequency over recent decades due to increased human development and shifting climatic patterns. The work presented here focuses on the impacts of a WUI fire on indoor air using field measurements of volatile organic compounds (VOCs) by Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF-MS). We found a slow decrease in VOC mixing ratios over the course of roughly 5 weeks starting 10 days after the fire, and those levels decreased to ∼20% of the initial indoor value on average.

View Article and Find Full Text PDF

Background: Very long-chain acyl-coenzyme A dehydrogenase deficiency (VLCADD) is a rare autosomal recessive disease associated with variants in the gene.

Methods: In December 2021, a neonate with VLCADD was identified via newborn screening in Xuzhou, China. Genetic testing and genetic family verification were performed via high-throughput sequencing combined with Sanger sequencing.

View Article and Find Full Text PDF

Alkylated polycyclic aromatic hydrocarbons (PAHs) are abundant constituents of many PAH mixtures and contribute to risk at contaminated sites. Despite their abundance, the movement of alkylated PAHs remains understudied relative to unsubstituted PAHs. In the present study, passive sampling devices were deployed in the air, water, and sediments at 11 locations across multiple seasons to capture spatial and temporal variability in the abundance and movement of alkylated PAHs at a Brownsfield creosote site in Oregon, USA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!