The filter elution technique using nondenaturing conditions is widely used to assay DNA double-strand break (DSB) induction and repair. It has been reported that in the measurement of strand breaks higher rates of elution and of initial rejoining are obtained at pH 9.6 compared to pH 7.2. In the present experiments neutral elution at pH 7.2 and 9.6 were compared in the assay of damage to DNA induced by X rays, 125I decay, and restriction enzyme digestion, in an effort to explain this discrepancy and to determine whether the higher rate of elution observed at pH 9.6 corresponds to a greater number of DSBs. X-ray damage to cellular DNA resulted in significantly different elution profiles at the two pH values. In contrast the elution profiles of the DSB induced by intragenomic 125I decays or restriction endonuclease were independent of the pH of the elution buffer. When gamma-irradiated SV40 DNA was exposed to pH 7.2 or 9.6 elution buffer prior to analysis by gel electrophoresis, a significantly greater number of DNA DSBs were detected in the DNA exposed to pH 9.6. We conclude that X and gamma radiation produce lesions (pH 9.6-labile lesions), in proportion to dose, that have the potential of becoming measurable DSBs following incubation under the mildly alkaline condition of pH 9.6. The data suggest that these lesions may result from single-hit events.

Download full-text PDF

Source

Publication Analysis

Top Keywords

elution
9
dna
8
gel electrophoresis
8
filter elution
8
strand breaks
8
greater number
8
elution profiles
8
elution buffer
8
dna exposed
8
measurement radiation-induced
4

Similar Publications

Unlabelled: Solid phase extraction technique is a widely used sample preparation technique for the extraction of components from complex food matrices. However, there are several parameters in SPE that leads to low recovery, and reproducibility, insufficiently clean extracts and evaporation of volatile compounds. These drawbacks can be addressed through the use of innovative techniques and instrumentation that offers improved efficiency and accuracy for isolation of active constituents from food and beverage samples.

View Article and Find Full Text PDF

Background: In clinical practice, imiquimod is used to treat Human Papillomavirus (HPV)-related lesions, such as condyloma and Cervical Intraepithelial Neoplasia (CIN). Metronidazole is the most commonly prescribed antibiotic for bacterial vaginosis. The study developed biodegradable imiquimod- and metronidazole-loaded nanofibrous mats and assessed their effectiveness for the topical treatment of cervical cancer, a type of HPV-related lesion.

View Article and Find Full Text PDF

Background: Extensive research has established obstructive sleep apnea (OSA) as a contributing factor to numerous cardiovascular and cerebrovascular diseases. However, whether OSA affects in-stent restenosis (ISR) after elective drug-eluting stenting is unclear. Therefore, the objective of this study was to examine the impact of OSA on ISR in patients with coronary heart disease (CHD) who underwent successful elective drug-eluting stent (DES) implantation.

View Article and Find Full Text PDF

A novel electrochemical microsensor was constructed on a traditional acupuncture needle (AN) and used to monitor a biomarker of the SARS-CoV-2-N protein. The reversible interaction of the borate bond between the -diol in this glycoprotein and the phenylboronic acid in 4-mercaptophenylboronic acid (4-MPBA) was accomplished. This interaction was applied to anchor the SARS-CoV-2-N protein onto 4-MPBA, which was covalently self-assemblied onto electrodeposited AuNPs by the S-Au bond.

View Article and Find Full Text PDF

The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!